Powered by GoogleTranslate

Inspection Detail

Inspection: 313172322 - Veolia Es Technical Solutions, L.L.C.

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 313172322
Report ID: 0522000
Date Opened: 05/04/2009

Site Address:
Veolia Es Technical Solutions, L.L.C.
4301 Infirmary Road
Miamisburg, OH 45342

Mailing Address:
P.O. Box 453, West Carrollton, OH 45449

Union Status: NonUnion

SIC:4953

NAICS: 562211/Hazardous Waste Treatment and Disposal


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/01/2009

Emphasis: N:Psmpqv

Case Closed: 01/09/2010


Related Activity
Type Activity Nr Safety Health
Referral 201956000 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 11 11
Current Violations 10 10
Initial Penalty $45,000 $0 $0 $0 $0 $45,000
Current Penalty $35,000 $0 $0 $0 $0 $35,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100038 C02 10/14/2009 12/02/2009 $5,000 $5,000 $0 I - Informal Settlement  
2. 01002 Serious 19100106 E06 I 10/14/2009 11/02/2009 $5,000 $5,000 $0 I - Informal Settlement Citation has been deleted.
3. 01003 Serious 19100119 E01 10/14/2009 03/02/2010 $5,000 $5,000 $0 I - Informal Settlement  
4. 01004 Serious 19100119 E03 III 10/14/2009 03/02/2010 $5,000 $5,000 $0 I - Informal Settlement  
5. 01005 Serious 19100119 E03 V 10/14/2009 03/02/2010 $0 $5,000 $0 I - Informal Settlement  
6. 01006 Serious 19100120 P08 IVC 10/14/2009 03/02/2010 $2,500 $2,500 $0 I - Informal Settlement  
7. 01007A Serious 19100146 C05 IIE2 10/14/2009 10/26/2009 $5,000 $5,000 $0 I - Informal Settlement  
8. 01007B Serious 19100146 D05 II 10/14/2009 10/26/2009 $0 $0 $0 I - Informal Settlement  
9. 01008 Serious 19100146 K01 V 10/14/2009 11/09/2009 $2,500 $2,500 $0 I - Informal Settlement  
10. 01009 Serious 19100147 C06 II 10/14/2009 03/02/2010 $2,500 $2,500 $0 I - Informal Settlement  
11. 01010 Serious 19100307 B01 10/14/2009 11/09/2009 $2,500 $2,500 $0 I - Informal Settlement  
12. 01011 Serious 19101200 H03 II 10/14/2009 12/02/2009 $5,000 $5,000 $0 -  

Investigation Summary

Investigation Nr: 201955812
Event: 05/03/2009
Two Employees Suffer Second Degree Burns in Fire

On May 3, 2009, Employee #1 was finishing up the distillation of a flammable solvent called tetrahydrofuran, while Employee #2 was working nearby. They noticed that a very loud whistling sound began to occur and that a large cloud of solvent vapor was beginning to form in and spread outward. There was an explosion and fire. Both employees sustained second degree burns. Employees #1 and #2 were hospitalized. The boiler room produced steam and hot oil which was pumped out to the Distillation Units to provide the heat. Surveillance videotapes suggested that flammable solvent vapor was drawn into the building became ignited in the Boiler Room.

Keywords: BURN, FLAMMABLE LIQUID, EXPLOSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313172322 Hospitalized injury Burn/Scald(Heat) Miscellaneous plant and system operators
2 313172322 Hospitalized injury Fracture Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.