Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail



Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $1,875 $0 $0 $0 $0 $1,875
Current Penalty $1,875 $0 $0 $0 $0 $1,875
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 4184 A 07/29/2010 08/03/2010 $1,875 $1,875 $0 -

Accident Investigation Summary
Summary Nr: 202551719 Event: 04/12/2010Employee Amputates Finger In Injection Molding Die
At 3:10 a.m. on May 12, 2010, Employee #1 was removing molding product from a plastic injection molding die. A time delayed die ejection pin not controlled by the interlock system continued to be operational after the interlock mechanism shut off power in order for Employee #1 to remove a molded promotional product from the Plastar TM-145G Injection Molding Machine Serial Number 1034070 die. As Employee #1 removed the molded product the ejection ping retracted and pinched and partially amputated the employees' right middle finger tip. The accident was reported to DOSH at 2:00 p.m. on May 12, 2010.
Keywords: amputated, pin, finger, molding machine, pinned, interlock, casting die
Inspection Degree Nature Occupation
1 313165854 Hospitalized injury Amputation Molding and casting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close