 Accident102590155    

Accident Investigation Summary
Summary Nr: 202551594Event: 04/19/2010Worker Is Burned From Flash Explosion In Fuel Line
On April 19, 2010, Employee #1, an operating engineer of Disneyland Resort, was repairing Locomotive Number 4. He was unclogging an obstructed fuel line using pressurized air to force the obstructing back into the firebox. The operation caused a flash explosion, and Employee #1 was hospitalized for first and second degree burns to his face, ears, and right arm.
Keywords: burn, flammable liquid, compressed air, clogged, explosion, arm, face
Inspection Degree Nature Occupation
1 313165243 Hospitalized injury Burn/Scald(Heat) Operating engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.