Powered by GoogleTranslate

Inspection Detail

Inspection: 313160582 - Dan'S Roofing, Inc.

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 313160582
Report ID: 0950631
Date Opened: 06/04/2009

Site Address:
Dan'S Roofing, Inc.
711 Wendt Terrace
Laguna Beach, CA 92651

Mailing Address:
19011 Mermack Avenue, Lake Elsinore, CA 92532

Union Status: NonUnion

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/02/2009

Emphasis:

Case Closed: 02/17/2011


Related Activity
Type Activity Nr Safety Health
Accident 102586997
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $0 $0 $0 $2,800 $0 $2,800
Current Penalty $0 $0 $0 $2,800 $0 $2,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 12/03/2009 01/05/2010 $350 $350 $0 -  
2. 01002 Other 1509 B 12/03/2009 01/05/2010 $350 $350 $0 -  
3. 01003 Other 1527 A01 F 12/03/2009 12/08/2009 $350 $350 $0 -  
4. 01004 Other 1726 D 12/03/2009 12/08/2009 $700 $700 $0 -  
5. 01005 Other 3395 E01 12/03/2009 01/05/2010 $350 $350 $0 -  
6. 01006 Other 3382 A 12/03/2009 01/05/2010 $700 $700 $0 -  

Investigation Summary

Investigation Nr: 202550836
Event: 06/04/2009
Employee Receives Burn from Hot Roofing Tar

At approximately 3:30 p.m. on June 4, 2009, an employee was tending a hot tar kettle that pumped tar to the roof through a pipe. The kettle was manufactured by Cleasby Manufacturing in February, 2006 and had Serial Number 12593. It indicated temperature range was 50-550 degrees F. No one witnessed the actual event. The employee was observed by a coworker who was also an uncle, running from the kettle, and that the kettle was on fire. The employee had been wearing a short sleeved T-shirt and no face protection when the hot tar ignited and blew out of the kettle. Although there was a temperature gauge to monitor, there was no indication that the employee was monitoring the kettle's temperature. Since the flash point of the tar is stated to be 540 degrees F, the temperature must have been that high, or higher, although employee's management stated that the temperature should not be allowed to get higher than 520 degrees Fahrenheit. The employee suffered second and third degree burns to his right arm and right side of his face when the hot tar splashed out of the kettle. The employee was hospitalized.

Keywords: ROOF, FLAMMABLE LIQUID, FACE, HAND, ASPHALT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313160582 Hospitalized injury Burn/Scald(Heat) Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close