Inspection Detail
Inspection: 313130809 - American Packaging Corporation
Inspection Information - Office: Madison Area Office
Site Address:
American Packaging Corporation
850 W. James Street
Columbus, WI 53925
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2754
NAICS: 323111/Commercial Gravure Printing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/01/2010
Emphasis:
Case Closed: 11/01/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100801901 | ||
| Complaint | 206859803 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $18,900 | $0 | $0 | $0 | $0 | $18,900 |
| Current Penalty | $12,000 | $0 | $0 | $0 | $0 | $12,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100106 E06 I | 04/16/2010 | 04/28/2010 | $0 | $6,300 | $0 | 05/07/2010 | F - Formal Settlement | Citation has been deleted. |
| 2. | 01001B | Serious | 19100252 A02 VIC | 04/16/2010 | 04/28/2010 | $0 | $0 | $0 | 05/07/2010 | F - Formal Settlement | Citation has been deleted. |
| 3. | 01002A | Serious | 5A0001 | 04/16/2010 | 04/28/2010 | $6,000 | $6,300 | $0 | 05/07/2010 | F - Formal Settlement | |
| 4. | 01002B | Serious | 5A0001 | 04/16/2010 | 04/28/2010 | $0 | $0 | $0 | 05/07/2010 | F - Formal Settlement | |
| 5. | 01002C | Serious | 5A0001 | 04/16/2010 | 04/28/2010 | $0 | $0 | $0 | 05/07/2010 | F - Formal Settlement | |
| 6. | 01002D | Serious | 5A0001 | 04/16/2010 | 04/28/2010 | $0 | $0 | $0 | 05/07/2010 | F - Formal Settlement | |
| 7. | 01003A | Serious | 19100119 K01 | 04/16/2010 | 04/28/2010 | $6,000 | $6,300 | $0 | 05/07/2010 | F - Formal Settlement | |
| 8. | 01003B | Serious | 19100252 A02 XIIIB | 04/16/2010 | 04/28/2010 | $0 | $0 | $0 | 05/07/2010 | F - Formal Settlement |
Investigation Summary
On October 18, 2009, an employee, a maintenance technician was finishing the work of installing a floor threshold plate in front of the Renzmann wash unit, Machine Type 300-35. The wash unit utilized ethyl acetate to clean rotogravure printing press components, and the steel plate was being installed to protect the concrete floor beneath. He was using a Milwaukee hand grinder to cut off leveling and anchor bolts were used in the installation of the floor plate. At approximately 6:05 p.m. an explosion occurred blowing the door off the wash unit and rupturing the side panels. The employee was thrown approximately 30 feet in the explosion, and died from his injuries.
Keywords: MAINTENANCE, EXPLOSION, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 313130809 | Fatality | Fracture | Machinery maintenance occupations |
Translate