Powered by GoogleTranslate

Inspection Detail

Inspection: 313012072 - Mark E. Milam Dba Performance Plus Consulting

Inspection Information - Office: Fairview Heights Area Office

 

Inspection Nr: 313012072
Report ID: 0524530
Date Opened: 05/20/2009

Site Address:
Mark E. Milam Dba Performance Plus Consulting
15879 Route 1
Mt Carmel, IL 62863

Mailing Address:
Po Box 847, Mt Carmel, IL 62863

Union Status: NonUnion

SIC:1381

NAICS: 213111/Drilling Oil and Gas Wells


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/24/2009

Emphasis: L:Piv, S:Electrical, S:Fall From Height, S:Powered Ind Vehicle

Case Closed: 09/25/2009


Related Activity
Type Activity Nr Safety Health
Accident 361106776
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,500 $0 $0 $0 $0 $1,500
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100333 C03 07/31/2009 08/06/2009 $1,500 $1,500 $0 -  
2. 01001B Serious 19100333 C03 IA1 07/31/2009 08/06/2009 $0 $0 $0 -  
3. 02001 Other 19100178 L06 07/31/2009 08/26/2009 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200841831
Event: 05/18/2009
Employee Is Electrocuted While Power Washing Building

At approximately 1:55 p.m. on May 18, 2009, Employee #1 and a coworker were pressure washing an office building in preparation for painting. Employee #1 was in an elevated work platform and was using a 3,000 psi LED 3530 power washer, while Employee #2 was operating the Caterpillar DP50K forklift. As they moved to the west (back) side of the building, the power washer's hose became caught in various materials and pallets that were staged on the north and northwest sides of the building. In an attempt to free the hose from the obstructions, Employee #1, still in an elevated position, pulled on the hose. In doing so, the hose either contacted a 7.2 kV power line or there was an arcing event. Employee #1 was electrocuted and killed.

Keywords: ELECTROCUTED, HOSE, INDUSTRIAL TRUCK, ELECTRIC SHOCK, ELEVATED WORK PLAT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313012072 Fatality Electric Shock Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close