Powered by GoogleTranslate

Inspection Detail

Inspection: 312966104 - Petro-Hunt, Llc

Inspection Information - Office: Bismarck Area Office

 

Inspection Nr: 312966104
Report ID: 0830300
Date Opened: 03/02/2009

Site Address:
Petro-Hunt, Llc
3.5 Miles Ne Of Town
Ray, ND 58849

Mailing Address:
1601 Elm Street Suite 3400, Dallas, TX 75201

Union Status: NonUnion

SIC:1311

NAICS: 211111/Crude Petroleum and Natural Gas Extraction


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/09/2009

Emphasis: L:Oilgas, S:Electrical

Case Closed: 11/09/2010


Related Activity
Type Activity Nr Safety Health
Accident 100332741
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 2 2
Initial Penalty $9,000 $0 $0 $0 $0 $9,000
Current Penalty $4,500 $0 $0 $0 $0 $4,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 07/13/2009 09/13/2010 $1,500 $3,000 $0 07/27/2009 F - Formal Settlement  
2. 01002 Serious 19100132 A 07/13/2009 08/17/2009 $3,000 $3,000 $0 07/27/2009 F - Formal Settlement Citation has been deleted.
3. 01003 Serious 19100307 C02 I 07/13/2009 09/13/2010 $3,000 $3,000 $0 07/27/2009 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200332179
Event: 02/28/2009
Employee Is Killed from Asphyxiation While Guarding Tank

On February 28, 2009, Employee #1 was involved in a tank gauging operation. As Employee #1 had just finished gauging a tank that was found to be full, he proceeded to divert the supply line to another tank. The shutoff valve blew out, releasing sour crude and hydrogen sulfide gas. Employee #1 was overcome by the released gasses and died from asphyxiation. Employee #1 discovered approximately fifteen feet from the valve. The incident investigation revealed that Employee #1 had been provided, by his employer, with a personal gas monitor, a 30-minute SCBA, and a cascade air line system, which were found inside the vehicle.

Keywords: MAINTENANCE, ASPHYXIATED, PPE, SUFFOCATED, INHALATION, EQUIPMENT FAILURE, TOXIC FUMES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312966104 Fatality Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.