Powered by GoogleTranslate

Inspection Detail

Inspection: 312868920 - Harris Rathole Service, L.P.

Inspection Information - Office: Lubbock Area Office

 

Inspection Nr: 312868920
Report ID: 0627400
Date Opened: 10/21/2009

Site Address:
Harris Rathole Service, L.P.
13 Miles S Of Midland On Hwy 349
Midland, TX 79701

Mailing Address:
P. O. Box 5442, Midland,, TX 79704

Union Status: NonUnion

SIC:1389

NAICS: 238910/Site Preparation Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/22/2009

Emphasis: L:Oilgas, S:Electrical

Case Closed: 02/16/2010


Related Activity
Type Activity Nr Safety Health
Accident 100814490
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $4,950 $0 $0 $0 $0 $4,950
Current Penalty $4,950 $0 $0 $0 $0 $4,950
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100151 B 12/23/2009 02/28/2010 $750 $750 $0 I - Informal Settlement  
2. 01002 Serious 19100332 B02 12/23/2009 02/28/2010 $2,100 $2,100 $0 I - Informal Settlement  
3. 01003A Serious 19100333 C03 IIIA 12/23/2009 02/28/2010 $2,100 $2,100 $0 I - Informal Settlement  
4. 01003B Serious 19100333 C03 IIIB 12/23/2009 02/28/2010 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200812931
Event: 10/21/2009
Employee Is Electrocuted by Power Lines

On October 21, 2009, Employee #1 was opening the lid of a toolbox on an air drilling rig, while the derrick was being raised. The derrick contacted 22 kV overhead power transmission lines, and caused Employee #1 to be electrocuted. Employee #1 was killed.

Keywords: DERRICK, ELECTRIC CABLE, ELECTROCUTED, OIL WELL DRILLING, GAS WELL DRILLING, OIL RIG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312868920 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close