Powered by GoogleTranslate

Inspection Detail

Inspection: 312679541 - I V Welding And Mechanical Inc

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 312679541
Report ID: 0950632
Date Opened: 09/02/2009

Site Address:
I V Welding And Mechanical Inc
7030 Gentry Rd
Calipatria, CA 92233

Mailing Address:
185 S 3rd, El Centro, CA 92243

Union Status: NonUnion

SIC:7699

NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/22/2009

Emphasis:

Case Closed: 02/15/2012


Related Activity
Type Activity Nr Safety Health
Accident 101076446
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 6 7
Current Violations 1 6 7
Initial Penalty $3,150 $0 $0 $5,670 $0 $8,820
Current Penalty $3,150 $0 $0 $1,670 $0 $4,820
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 10/23/2009 11/02/2009 $1,000 $5,000 $0 11/10/2009 F - Formal Settlement  
2. 01002 Other 23400017 A 10/23/2009 11/27/2009 $195 $195 $0 -  
3. 01003 Other 23400022 B 10/23/2009 11/27/2009 $130 $130 $0 -  
4. 01004 Other 3203 B02 10/23/2009 11/27/2009 $175 $175 $0 -  
5. 01005 Other 3664 A 10/23/2009 11/27/2009 $85 $85 $0 -  
6. 01006 Other 6151 C01 10/23/2009 11/27/2009 $85 $85 $0 -  
7. 02001 Serious 3210 A 10/23/2009 11/27/2009 $3,150 $3,150 $0 -  

Investigation Summary

Investigation Nr: 201074374
Event: 04/24/2009
Employee Receives Burns from Welding Exposion

At approximately 8:00 p.m. on April 24, 2009, Employee #1 was assisting a coworker, a welder, with the installation of a new flange at a geothermal energy generation site in Calipatria, CA. The task was to cut a hole into an existing injection well pipe and weld the new flange upon it. A few days before, the pipe had been emptied of fluid and closed by valves on either side of the weld location. The hole was cut by the welder, then the metal and brine scale buildup behind it were removed and the edge of the cut section was smoothed with a grinder. The employee was then instructed to hold the flange over the hole to level it for the welder. As the welder struck the flange with the arc, an explosion occurred and ejected the flange. It struck Employee #1 in the chest with great force, causing blunt force injuries and third degree burns. The burns to his chest encompass approximately 6 inches in diameter. He was transported to Pioneers Memorial Hospital in Brawley, CA, where he underwent burn treatment and was hospitalized.

Keywords: BURN, WELDING, EXPLOSION, PIPE, STRUCK BY, ARC WELDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312679541 Hospitalized injury Burn/Scald(Heat) Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.