Powered by GoogleTranslate

Inspection Detail

Inspection: 311876643 - The Electric Materials Company

Inspection Information - Office: Erie Area Office

 

Inspection Nr: 311876643
Report ID: 0336000
Date Opened: 04/09/2010

Site Address:
The Electric Materials Company
50 South Washington Street
North East, PA 16428

Mailing Address:
P.O. Box 390, North East, PA 16428

Union Status: Union

SIC:3351

NAICS: 331421/ Copper Rolling, Drawing, and Extruding


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/23/2010

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 09/21/2010


Related Activity
Type Activity Nr Safety Health
Referral 200387355 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $5,600 $0 $0 $0 $0 $5,600
Current Penalty $4,480 $0 $0 $0 $0 $4,480
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 08/12/2010 09/15/2010 $4,480 $5,600 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200380996
Event: 04/08/2010
Employee Suffers Chemical Burns to Respiratory System

At approximately 6:00 a.m. on April 8, 2010, Employee #1 was transferring Bright-Dip Acid solution from a two-piece drum to a one-piece drum using an electric pump. A reaction occurred as the hazardous substance began to pour into the one-piece drum and the liquid began to spew from the drums creating an orange chemical cloud. Employee #1 asked the supervisor to unplug the pump to stop the release of the liquid. Then, Employee #1 attempted to contain and clean the hazardous substance, while a coworker opened a garage door to "air" out the chemical cloud. The chemical cloud traveled up the hallway to other departments in the building, exposing all employees to the hazardous substance release. An announcement was then made for all employees to evacuate the building. The local fire department and HAZMAT team were called to the site to help contain and clean the hazardous substance. A total of twenty employees were taken to local hospitals, St. Vincent Health Center and Hamot Hospital, for decontamination and observation. Employee #1 was working in the Plating Department was treated and held for approximately one week due to chemical burns to his respiratory system.

Keywords: RESPIRATORY, DRUM, ELECTRIC PUMP, CHEMICAL BURN, CHEMICAL REACTION, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311876643 Non Hospitalized injury Burn(Chemical) Milling and planing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close