Powered by GoogleTranslate

Inspection Detail

Inspection: 311868038 - Full Spectrum Lighting And Electrical Services

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 311868038
Report ID: 0950621
Date Opened: 02/27/2009

Site Address:
Full Spectrum Lighting And Electrical Services
629 Main St
Placerville, CA 95667

Mailing Address:
104 Aromas Rd, Aromas, CA 95004

Union Status: NonUnion

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/15/2009

Emphasis: S:Construction (Cship)

Case Closed: 03/14/2014


Related Activity
Type Activity Nr Safety Health
Accident 102512928
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $15,300 $0 $0 $0 $0 $15,300
Current Penalty $4,950 $0 $0 $0 $0 $4,950
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 1675 J 05/08/2009 05/13/2009 $450 $4,500 $0 05/19/2009 F - Formal Settlement  
2. 02001 Serious 1675 K 05/08/2009 05/13/2009 $4,500 $10,800 $0 05/19/2009 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202488094
Event: 02/27/2009
Employee Falls from Ladder and Dies

On February 27, 2009, Employee #1 was dismantling deenergized panels from outside a commercial building with a coworker. An aluminum conduit, 15.5 ft long and 4 in. in diameter, needed to be removed. This length of conduit contained four 350 MCM copper cables. The total weight of the conduit was approximately 127 pounds, according to the manufacturer's literature. A conduit rose vertically from the right side of a decommissioned electrical panel and was too heavy to lift manually. Therefore, the employee mounted an extension ladder and worked from its third rung, approximately 18 ft high. He pushed the conduit in a direction away from the ladder and lost his balance. He fell from the ladder and landed on his head. The coworker called for emergency medical assistance. Employee #1 was transported to a local hospital, where he was pronounced dead. The employee was not using any fall protection equipment.

Keywords: CONDUIT, LADDER, FALL, FALL PROTECTION, LOST BALANCE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311868038 Fatality Other Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.