Powered by GoogleTranslate

Inspection Detail

Inspection: 311682926 - Vision Telecommunications, Inc.

Inspection Information - Office: Charleston Area Office

 

Inspection Nr: 311682926
Report ID: 0316400
Date Opened: 10/14/2011

Site Address:
Vision Telecommunications, Inc.
1749 Mile Fork Road
Pinch, WV 25156

Mailing Address:
12058 San Jose Blvd. Suite 902, Jacksonville, FL 32223

Union Status: NonUnion

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/12/2012

Emphasis:

Case Closed: 05/16/2012


Related Activity
Type Activity Nr Safety Health
Accident 100632843
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 1 1
Initial Penalty $9,800 $0 $0 $0 $0 $9,800
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100268 B07 04/12/2012 04/18/2012 $4,900 $4,900 $0 I - Informal Settlement Citation has been deleted.
2. 01001B Serious 19100268 J03 04/12/2012 04/18/2012 $0 $0 $0 I - Informal Settlement Citation has been deleted.
3. 01002 Serious 19100268 C03 04/12/2012 04/20/2012 $4,900 $4,900 $0 I - Informal Settlement Citation has been deleted.
4. 02001 Other 19100157 C04 04/12/2012 04/18/2012 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200632438
Event: 10/14/2011
Employee Is Electrocuted in Contact with Overhead Power Line

On October 14, 2011, Employee #1 and Coworker #1 were installing new coax span cable between two poles in a residential community. Employee #1 was working in a bucket of a 1994 GMC 7500 Top Kick Truck with a Telsta T40C boom, and Coworker #1 was located on the ground. The coax span cable was positioned below two existing power lines: a primary power line positioned at a height of 31 feet, 2.5 inches from the ground that was energized to 19,900 volts and a secondary power line positioned at a height of 21 and a half feet from the ground that was energized to 120 volts. The coax span cable was being installed at a height of approximately 17 to 18 feet from ground level. At the time of the accident, Employee #1 encountered a tree while installing the new coax span cable approximately 30 feet down the line. Coworker #1 provided Employee #1 with a pair of pruning tools to trim branches away from the location where the coax cable was to be installed. Employee #1 instructed Coworker #1 to get back into the truck. Coworker #1 sat down inside the truck and while closing the door, he heard a loud buzzing sound. Coworker #1 looked out of the truck and saw Employee #1 lying inside the bucket, which was located next to the primary power line. Coworker #1 attempted to communicate verbally with Employee #1 but was unsuccessful. Coworker #1 operated the manual controls and lowered the bucket to the ground. Coworker #1 contacted emergency services. Emergency services arrived and determined that Employee #1 had been killed.

Keywords: OVERHEAD POWER LINE, ELECTROCUTED, TREE, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311682926 Fatality Electric Shock Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.