Powered by GoogleTranslate

Inspection Detail

Inspection: 311656029 - B & T Farms

Inspection Information - Office: Fremont District Office

 

Inspection Nr: 311656029
Report ID: 0950612
Date Opened: 05/30/2008

Site Address:
B & T Farms
6020 B Frazier Lake Rd.
Gilroy, CA 95020

Mailing Address:
P.O. Box 1429, Gilroy, CA 95021

Union Status: NonUnion

SIC:0761

NAICS: 115115/Farm Labor Contractors and Crew Leaders


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/13/2008

Emphasis: S:Agriculture (Aship)

Case Closed: 10/28/2008


Related Activity
Type Activity Nr Safety Health
Accident 102582244
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $14,400 $0 $0 $930 $0 $15,330
Current Penalty $14,400 $0 $0 $930 $0 $15,330
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 09/08/2008 10/01/2008 $310 $310 $0 -  
2. 01002 Other 3702 G 09/08/2008 10/01/2008 $310 $310 $0 -  
3. 01003 Other 5194 E01 09/08/2008 10/01/2008 $310 $310 $0 -  
4. 02001 Serious 5416 C 09/08/2008 10/01/2008 $14,400 $14,400 $0 -  
5. 03001 Other 14300029 A 09/08/2008 10/01/2008 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 202527875
Event: 05/26/2008
Employee Receives Burns in Flash Fire

At approximately 8:30 p.m. on May 26, 2008, Employee #1, a mechanic, and coworker were attempting to extinguish an engine fire on the company vehicle, which was a 1995 Chevrolet pickup truck. The vehicle was parked at the coworker's home, and Employee #1 obtained a water truck to extinguish the fire. The water truck, which was a Chevrolet flatbed truck, had a pressure pump motor that ran empty on fuel. Employee #1 was refueling the pump motor with a 2-gallon plastic container with spout near an ignition source. As Employee #1 filled the tank, a flash fire occurred that caused burns to his forearms, hands, stomach, and face. He was transported to a medical center, where he received treatment and was hospitalized.

Keywords: BURN, ABDOMEN, FLAMMABLE LIQUID, FIRE, FOREARM, MECHANIC, ENGINE, FIGHTING, HAND, WATER TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311656029 Hospitalized injury Burn/Scald(Heat) Specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.