Powered by GoogleTranslate

Inspection Detail

Inspection: 311209100 - Avion Water Company Inc

Inspection Information - Office: Bend

 

Inspection Nr: 311209100
Report ID: 1054115
Date Opened: 03/28/2008

Site Address:
Avion Water Company Inc
60813 Parrell Rd
Bend, OR 97702

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:4941

NAICS: 221310/Water Supply and Irrigation Systems


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/04/2008

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/04/2008


Related Activity
Type Activity Nr Safety Health
Referral 201704301 Yes

Investigation Summary

Investigation Nr: 201702479
Event: 03/20/2008
Employee Receives an Electric Shock

At approximately 2:00 p.m. on March 20, 2008, Employee #1 was cutting thru a 4 in. water line with a handsaw. He did not realize that there was a 7,200 volt power line tucked under the two 4 in. water lines next to each other. As he cut thru the outer insulation, he received an electric shock. Employee #1 was transported to a medical center, where he underwent treatment and was released.

Keywords: ELECTRIC SAW, ELECTRIC SHOCK, WATER PIPE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311209100 Non Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.