Powered by GoogleTranslate

Inspection Detail

Inspection: 310883780 - Smith Built Construction, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 310883780
Report ID: 0420600
Date Opened: 02/08/2007

Site Address:
Smith Built Construction, Inc.
2034 Oxendine Rd.
Zolfo Springs, FL 33890

Mailing Address:
141 Owen Circle South, Auburndale, FL 33823

Union Status: NonUnion

SIC:1521

NAICS: 236115/New Single-Family Housing Construction (except Operative Builders)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/04/2007

Emphasis: L:Ohpwrlne, S:Electrical

Case Closed: 05/13/2009


Related Activity
Type Activity Nr Safety Health
Accident 102486594
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 4 1 5
Initial Penalty $12,800 $0 $0 $1,500 $0 $14,300
Current Penalty $9,500 $0 $0 $750 $0 $10,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260451 B01 05/07/2007 05/10/2007 $750 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19260451 F06 05/07/2007 05/10/2007 $4,000 $4,900 $0 I - Informal Settlement  
3. 01003 Serious 19260451 G01 05/07/2007 05/10/2007 $750 $1,500 $0 I - Informal Settlement  
4. 01004 Serious 19260454 A 05/07/2007 05/20/2007 $4,000 $4,900 $0 I - Informal Settlement  
5. 02001 Other 19040039 A 05/07/2007 05/10/2007 $750 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202461893
Event: 01/17/2007
Employee electrocuted when metal rod contacts power line

On January 17, 2007, Employee #1 was standing on a 20 ft high scaffold erected next to the chimney on the west side of a new home under construction. An overhead power line ran next to the home, 8 ft out from the chimney and between 3 ft and 5 ft above the scaffold. Employee #1 was inserting a 17 ft 7 in. reinforcing rod down the chimney when he raised the rod and it contacted the power line. Employee #1 was electrocuted.

Keywords: CLEARANCE, OVERHEAD POWER LINE, ELECTRICAL, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, METAL POLE, ELEC CIRC PART--MISC, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310883780 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close