Inspection Detail
Inspection: 310815840 - Schilling Corporation
Inspection Information - Office: San Diego District Office
Site Address:
Schilling Corporation
College & Cannon
Oceanside, CA 92054
Mailing Address:
697 Greenfield Dr, El Cajon, CA 92021
Union Status: NonUnion
SIC:1623
NAICS: 237130/Power and Communication Line and Related Structures Construction
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/18/2008
Emphasis:
Case Closed: 06/18/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101071264 |
Investigation Summary
At approximately 12:00 p.m. on March 14, 2008, an employee was cutting a pressurized gas line connection when the cap popped off the end, striking the employee in the face. The employee had lacerations to his lips from the cap, and some of the escaped pressurized gas entered his body through his mouth causing subcutaneous and mediastinal air in his body. The employee was transported to Grossmont Hospital in La Mesa, CA. The employee was hospitalized and treated for laceration.
Keywords: CONSTRUCTION, LACERATION, STRUCK BY, FACE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310815840 | Hospitalized injury | Other | Construction trades, n.e.c. |