Investigation Summary

Investigation Nr: 310810064
Event: 07/26/2006
Worker Falls from Ladder and Fractures Ankle and Leg

On July 26, 2006, an employee was repairing a truss on the second floor of a building. When he descended a ladder, he missed a rung and fell approximately 6 ft to the ground. He fractured his ankle, as well as his tibia and fibula. He had surgery, and was hospitalized at Tricity hospital.

Keywords: FRACTURE, MAINTENANCE, REPAIR, TIBIA, LADDER, DESCENDING, FALL, LOST BALANCE, ANKLE, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310810064 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.