Powered by GoogleTranslate

Inspection Detail

Inspection: 310754288 - Gas Field Specialists, Inc

Inspection Information - Office: Syracuse Area Office

 

Inspection Nr: 310754288
Report ID: 0215800
Date Opened: 03/11/2008

Site Address:
Gas Field Specialists, Inc
7535 Eagle Valley Road
Savona, NY 14879

Mailing Address:
1171 State Route 44, Shinglehouse, PA 16748

Union Status: NonUnion

SIC:1389

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/19/2008

Emphasis: L:Oilgas, S:Amputations

Case Closed: 10/17/2008


Related Activity
Type Activity Nr Safety Health
Accident 100882026
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $6,300 $0 $0 $0 $0 $6,300
Current Penalty $4,095 $0 $0 $0 $0 $4,095
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 08/28/2008 09/03/2008 $2,275 $3,500 $0 I - Informal Settlement  
2. 01002 Serious 19100023 C01 08/28/2008 09/03/2008 $910 $1,400 $0 I - Informal Settlement  
3. 01003 Serious 19100023 D01 III 08/28/2008 09/03/2008 $910 $1,400 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200881472
Event: 03/10/2008
Four Employees Burned in Explosion

Some employees were drilling a 160-millimeter-diameter access hole to an underground salt formation used as a storage container for liquid propane and butane. The top of the storage container was 902 meters below the surface. At a depth of approximately 872 meters, the drill string apparently encountered a pocket of liquid propane, which escaped to the surface before the blow-off preventer could be activated. The propane evaporated, and an ignition source ignited the vapor. The resulting explosion and fire burned three employees of Gas Field Specialists, Inc., and one employee of Inergy Midstream, LLC. Three of the burned employees were hospitalized, and one was treated and released.

Keywords: BURN, EXPLOSION, DRILL RIG--NON-OIL, PROPANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310754288 Hospitalized injury Burn/Scald(Heat) Drillers, earth
2 310754288 Hospitalized injury Burn/Scald(Heat) Drillers, earth
3 310754288 Non Hospitalized injury Burn/Scald(Heat) Drillers, earth
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close