Powered by GoogleTranslate

Inspection Detail

Inspection: 310604293 - California Steel Industries, Inc.

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 310604293
Report ID: 0950633
Date Opened: 09/22/2008

Site Address:
California Steel Industries, Inc.
14000 San Bernardino Ave
Fontana, CA 92335

Mailing Address:
Po Box 5080, Fontana, CA 92335

Union Status: NonUnion

SIC:3312

NAICS: 332312/Fabricated Structural Metal Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/22/2009

Emphasis:

Case Closed: 07/22/2009


Related Activity
Type Activity Nr Safety Health
Accident 102554136
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $0 $0 $0 $560 $0 $560
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 01/22/2009 02/09/2009 $0 $560 $0 02/11/2009 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 202449468
Event: 09/15/2008
Employee Experiences Heat Stress

At approximately about 2:00 p.m. on September 15, 2008, Employee #1, an electrician, felt ill and dizzy due to heat exhaustion. Earlier, at about 11:00 a.m., he began threading a pipe for the wiring to the fire suppression sensors for the fume exhaust ducts. These ducks were supporting one of the steel pickling lines, which operated a steel fabrication facility, located in Fontana, California. In the morning, Employee #1 took frequent rest and water breaks in air conditioned areas. However, after lunch he did not take breaks frequently in order to complete this work before the end of his shift. Employee #1 could not recall drinking anything after the lunch. In-house emergency medical technicians provided initial evaluation and aid to Employee #1. He was transported to the San Antonio Community Hospital in Upland, California, where he was hospitalized for an apparent heat stress illness for two days.

Keywords: FIRE EXT SYSTEM, ELECTRICIAN, FATIGUE, DIZZINESS, PIPE, HEAT EXHAUSTION, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310604293 Hospitalized injury Heat Exhaustion Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.