Powered by GoogleTranslate

Inspection Detail

Inspection: 310495163 - Serra Manufacturing Corp

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 310495163
Report ID: 0950642
Date Opened: 04/30/2009

Site Address:
Serra Manufacturing Corp
3039 E Las Hermanas St
Rancho Dominguez, CA 90224

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3452

NAICS: 332722/ Bolt, Nut, Screw, Rivet, and Washer Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/13/2009

Emphasis:

Case Closed: 08/28/2011


Related Activity
Type Activity Nr Safety Health
Accident 102475761
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $18,000 $0 $0 $275 $0 $18,275
Current Penalty $14,580 $0 $0 $0 $0 $14,580
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 4237 B 07/13/2009 08/15/2009 $0 $275 $0 07/27/2009 F - Formal Settlement  
2. 02001 Serious 4208 G02 07/10/2009 07/20/2009 $180 $3,600 $0 07/27/2009 F - Formal Settlement  
3. 03001 Serious 3328 A 07/13/2009 07/23/2009 $14,400 $14,400 $0 07/27/2009 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202455416
Event: 04/23/2009
Employee Injures Finger While Operating Polishing Wheel

At approximately 1:20 p.m. on April 23, 2009, Employee #1, a deburring clerk, was polishing a batch of metal gasket at an aerospace parts manufacturing facility. The metal gasket had an outer diameter of approximately 5.5 in. and internal diameter of approximately 5.3 in. with a thickness of 0.015 in. The machine was produced by Dayton, Model Number 6K482B, and Manufacturing Number C55JXFDR-2958, rpm 3450. The polishing wheel was manufactured by Scotch Brite, Product Number 7S FIN. He was holding the edge of the part at approximately 45 degree angle to the wheel, when the part became entangled in the polishing wheel. The part rotated with the wheel, striking his hand and injuring his index finger up to the first knuckle. He was taken by ambulance to Long Beach Memorial Hospital, where he had surgery involving the amputation of his right index finger up to the first knuckle. After the surgery, he was hospitalized.

Keywords: AMPUTATED, FINGER, STRUCK BY, GRINDING WHEEL, GRINDING MACHINE, MACHINE--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310495163 Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.