Powered by GoogleTranslate

Inspection Detail

Inspection: 310212501 - Louis Dreyfus Citrus Inc.

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 310212501
Report ID: 0418800
Date Opened: 11/15/2006

Site Address:
Louis Dreyfus Citrus Inc.
19100 S.W. Warfield Blvd.
Indiantown, FL 34956

Mailing Address:
P.O. Box 1980, Indiantown, FL 34956

Union Status: NonUnion

SIC:2092

NAICS: 311712/Fresh and Frozen Seafood Processing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/11/2007

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/27/2007


Related Activity
Type Activity Nr Safety Health
Accident 100679216
Referral 200687150 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $9,800 $0 $0 $0 $0 $9,800
Current Penalty $9,800 $0 $0 $0 $0 $9,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C04 I 05/11/2007 06/07/2007 $4,900 $4,900 $0 -  
2. 01002 Serious 19100147 C07 I 05/11/2007 06/07/2007 $4,900 $4,900 $0 -  

Investigation Summary

Investigation Nr: 200676401
Event: 11/15/2006
Employee Is Burned When Evaporator Tank Ruptures

At approximately 6:30 a.m. on November 15, 2006, Employee #1 and two coworkers were working below an evaporator tank on the pump motor, replacing a coupling on a waster evaporator system. This necessary repair was due to the pumps inability to remove the build up of the water from the tank. The tank, which was mounted about 11 feet from the ground, was cylindrical in shape and measured approximately 6-feet wide by 13.5-feet high. The tank had severe metal deterioration that was evident by severe rust and pervious welding repairs. During their work, the system was still running with no lockout or tagout procedures in place. Therefore, water continued to fill the tank as they worked. Due to the weight of the water, the tank ruptured, rapidly releasing several hundred gallons of water that measured about 200 to 300 degrees Fahrenheit. Employee #1 was severely burned. He was taken to a local hospital, where he was hospitalized and treated for his injuries. The accident investigation reported observing two tears at the bottom of the tank, sustained from the rupture, which began at the outer edges and ran towards the center of the tank.

Keywords: BURN, REPAIR, PPE, EQUIPMENT FAILURE, LOCKOUT, RUPTURE, STRUCK BY, TANK, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310212501 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.