Powered by GoogleTranslate

Inspection Detail

Inspection: 310078282 - J. & J., Incorporated

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 310078282
Report ID: 0352440
Date Opened: 07/17/2006

Site Address:
J. & J., Incorporated
7932 Reichs Ford Road, Bay #3
Frederick, MD 21704

Mailing Address:
10610 Harp Road, Walkersville, MD 21793

Union Status: NonUnion

SIC:7349

NAICS: 562111/Solid Waste Collection


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/19/2006

Planning Guide: Safety-Manufacturing

Emphasis: S:General Industry, S:Struck-By

Case Closed: 10/31/2006


Related Activity
Type Activity Nr Safety Health
Accident 102359528
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $5,400 $0 $0 $0 $0 $5,400
Current Penalty $2,700 $0 $0 $0 $0 $2,700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100169 B02 09/06/2006 09/16/2006 $1,350 $2,700 $0 I - Informal Settlement  
2. 01002 Serious 19100169 B03 IV 09/06/2006 09/11/2006 $1,350 $2,700 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202362570
Event: 07/17/2006
Explosion Results in Employee Leg Amputation

Employee #1 was injured when the 300-gallon air receiver of an air compressor unit ruptured resulting in severe injuries to both his legs The accident was caused by rust inside the receiver that weakened the steel due to the receiver not been drained. The safety valve was inoperative due to corrosion from not being tested. The pressure gauge was stuck on 90 psi. Employee #1 was transported to the hospital where his left leg had to be amputated below the knee and the right leg required several pins. Employee #1 was hospitalized.

Keywords: COMPRESSOR, AIR RECEIVER, AMPUTATED, COMPRESSED AIR, EQUIPMENT FAILURE, EXPLOSION, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310078282 Hospitalized injury Amputation Specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close