Inspection: 309904126 - Tank & Refinery Services

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 309904126
Report ID: 0950635
Date Opened: 10/25/2006

Site Address:
Tank & Refinery Services
961 La Paloma St
Wilmington, CA 90744

Mailing Address:
9703 Norwalk Blvd, Santa Ana, CA 90670

Union Status: NonUnion

SIC:7699

NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/25/2006

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/21/2008


Related Activity
Type Activity Nr Safety Health
Accident 362413643
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 1 1 2
Initial Penalty $24,635 $0 $0 $360 $0 $24,995
Current Penalty $810 $0 $0 $810 $0 $1,620
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 01/18/2007 02/06/2007 $0 $360 $0 01/29/2007 F - Formal Settlement Citation has been deleted.
2. 02001 Other 4999 B01 01/18/2007 01/30/2007 $810 $20,250 $0 01/29/2007 F - Formal Settlement  
3. 03001 Serious 5002 01/18/2007 02/06/2007 $810 $4,385 $0 01/29/2007 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201038494
Event: 09/07/2006
Employee Is Struck by Falling Metal Vent, Suffers Fractures

At approximately 10:00 a.m. on September 7, 2006, Employee #1 was part of a crew repairing the internal floating roof on a tank by standing on the top of the internal roof. The crew had cut an 18-in. by 6-ft hole in the fixed external roof and was passing materials to the welders inside. The external vent was being readied to pass down the hole by mistake, having been intended for the external roof. There were several accounts of how the pick was rigged, but it was agreed that the nylon web sling allowed the part to slip out and fall through the exterior roof opening to the floating roof, where it struck Employee #1 in the back, fracturing three ribs which in turn punctured his liver. Employee #1 was hospitalized.

Keywords: FRACTURE, RIGGING, LIVER, RIB, MECH MAT HANDLING, STRUCK BY, FALLING OBJECT, CRANE, PUNCTURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309904126 Hospitalized injury Fracture Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.