Inspection Detail
Inspection: 309544674 - Crocket Construction
Inspection Information - Office: Dallas Area Office
Site Address:
Crocket Construction
850 Pioneer
Irving, TX 75061
Mailing Address:
523 Willow Lane, Irving, TX 75061
Union Status: NonUnion
SIC:1771
NAICS: 238110/Poured Concrete Foundation and Structure Contractors
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/27/2007
Planning Guide: Safety-Construction
Emphasis: S:Silica, L:Constr6, L:Silica, S:Electrical
Case Closed: 11/18/2013
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100784131 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
| Current Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19101200 E01 | 12/11/2007 | 01/08/2008 | $750 | $750 | $0 | - | ||
| 2. | 01002 | Serious | 19260416 A01 | 12/11/2007 | 12/19/2007 | $1,500 | $1,500 | $0 | - | ||
| 3. | 01003 | Serious | 19260416 A03 | 12/11/2007 | 01/08/2008 | $750 | $750 | $0 | - |
Investigation Summary
On June 26, 2007, Employee #1 and his coworkers were pouring an 80-foot-long by 40-foot-wide concrete slab for the foundation of a new metal building. The company had already finished pouring the footings and grade beams, before starting on the slab. Employee #1 was helping to guide the concrete pump hose, when the hydraulic boom of the concrete pump contacted a transformer. Employee #1 was electrocuted and killed. Although the work was being performed near or around the overhead power line, the company had not deenergized and grounded the power line and transformer. They also had not erected insulating barriers to prevent physical contact with the power line and transformer. The employer had not maintained a 10-foot clearance between the concrete pump boom and the overhead power line and transformer. In addition, a person was not designated to observe the clearance between the boom and power line and give timely warnings to the pump operator.
Keywords: CLEARANCE, CONCRETE PUMP, OVERHEAD POWER LINE, SIGNALMAN, BOOM, BARRIER GUARD, ELECTROCUTED, CONSTRUCTION, LOCKOUT, TRANSFORMER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309544674 | Fatality | Electric Shock | Occupation not reported |