Powered by GoogleTranslate

Inspection Detail

Inspection: 309539377 - Adesa Texas Dba Adesa Dallas

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 309539377
Report ID: 0626300
Date Opened: 07/27/2006

Site Address:
Adesa Texas Dba Adesa Dallas
1224 Big Town Blvd.
Mesquite, TX 75149

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5012

NAICS: 423110/Automobile and Other Motor Vehicle Merchant Wholesalers


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/27/2006

Emphasis:

Case Closed: 09/18/2007


Related Activity
Type Activity Nr Safety Health
Accident 100783851
Complaint 205265317 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $13,500 $0 $0 $0 $0 $13,500
Current Penalty $9,855 $0 $0 $0 $0 $9,855
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100022 A02 01/19/2007 01/31/2007 $900 $1,800 $0 I - Informal Settlement  
2. 01001B Serious 19100022 C 01/19/2007 01/31/2007 $0 $0 $0 I - Informal Settlement  
3. 01002A Serious 19100132 A 01/19/2007 01/31/2007 $675 $1,350 $0 I - Informal Settlement  
4. 01002B Serious 19100132 F01 01/19/2007 01/31/2007 $0 $0 $0 I - Informal Settlement  
5. 01003 Serious 19100303 F 01/19/2007 01/31/2007 $1,440 $1,800 $0 I - Informal Settlement  
6. 01004A Serious 19100304 F04 01/19/2007 01/31/2007 $3,600 $4,500 $0 I - Informal Settlement  
7. 01004B Serious 19100305 G01 IIID 01/19/2007 01/31/2007 $0 $0 $0 I - Informal Settlement  
8. 01005A Serious 19100332 B01 01/19/2007 01/31/2007 $1,800 $2,250 $0 I - Informal Settlement  
9. 01005B Serious 19100333 A 01/19/2007 01/31/2007 $0 $0 $0 I - Informal Settlement  
10. 01006 Serious 19100333 C07 01/19/2007 01/31/2007 $1,440 $1,800 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200783900
Event: 07/29/2006
Employee Is Shocked by Energized Fixture, Later Dies

On July 26, 2006, Employee #1, a maintenance technician, was repairing a broken chain on a hanging fluorescent light fixture. The conduit connecting the light fixture broke, apparently causing the inside energized wires to energize the metal light fixture. Employee #1 was shocked, after contacting the light fixture. Employee #1 died on July 29, 2006.

Keywords: REPAIR, CONDUIT, ELECTROCUTED, LIGHTING FIXTURE, LOCKOUT, ELECTRIC SHOCK, BROKEN CHAIN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309539377 Fatality Electric Shock Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close