Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 309443943 - Harsco - American Welding & Tank

Inspection Information - Office: Toledo

Nr: 309443943Report ID: 0524700Open Date: 10/31/2006

Harsco - American Welding & Tank
721 Graham Drive
Fremont, OH 43420
Union Status: Union
SIC: 3443/Fabricated Plate Work (Boiler Shops)
NAICS: 332420/Metal Tank (Heavy Gauge) Manufacturing

Inspection Type:Referral
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:11/20/2006
Close Case:02/16/2007

Related Activity:TypeIDSafetyHealth
 Referral202099073 Yes  

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $5,000 $0 $0 $0 $0 $5,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
Deleted 1. 01001 Serious 5A0001 01/26/2007 01/31/2007 $5,000 $5,000 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 202087987Event: 10/31/2006Worker Is Burned When Propane Gas Release Ignites
At approximately 6:45 a.m. on October 31, 2006, an employee for Harsco-American Welding & Tank, did not flare and remove at least one valve from a 500-gallon propane tank before bringing it into a building. Once inside the building, the employee removed the pressure relief valve. After the valve was removed, propane gas was released from the tank, and a gas-fired heater, located in the ceiling of the building, ignited the gas. The employee burned his hands and face. He was not hospitalized.
Keywords: burn, venting, valve, propane, face, tank, hand, pressure release
Inspection Degree Nature Occupation
1 309443943 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close