Powered by GoogleTranslate

Inspection Detail

Inspection: 309339349 - Niagara Cutter, Inc.

Inspection Information - Office: Erie Area Office

 

Inspection Nr: 309339349
Report ID: 0336000
Date Opened: 08/28/2007

Site Address:
Niagara Cutter, Inc.
150 South Fifth Street
Reynoldsville, PA 15851

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3545

NAICS: 333515/Cutting Tool and Machine Tool Accessory Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/30/2007

Emphasis: S:Electrical, S:Noise, S:Powered Ind Vehicle, S:Struck-By

Case Closed: 03/07/2008


Related Activity
Type Activity Nr Safety Health
Referral 200386084 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $3,750 $0 $0 $0 $0 $3,750
Current Penalty $2,625 $0 $0 $0 $0 $2,625
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 02/19/2008 02/22/2008 $1,840 $2,625 $0 I - Informal Settlement  
2. 01002A Serious 19101200 F05 I 02/19/2008 03/25/2008 $785 $1,125 $0 I - Informal Settlement  
3. 01002B Serious 19101200 F05 II 02/19/2008 03/25/2008 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200380772
Event: 08/28/2007
Employee Is Burned from Cnc Machine Fire

At approximately 12:15 a.m. on August 28, 2007, Employee #1 was operating a Walter CNC machine. The coolant pump was not working due to a defective interlock on the front door. An explosion occurred when the circulating coolant, circlene 67, ignited during grinding operations on the flutes. Employee #1 suffered second and third degree burns to his head and was hospitalized.

Keywords: GRINDER, HEAD, FIRE, EXPLOSION, STRUCK BY, GRINDING MACHINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309339349 Hospitalized injury Burn/Scald(Heat) Precision grinders, fitters and tool sharpeners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.