Powered by GoogleTranslate

Inspection Detail

Inspection: 309298677 - Hertz Equipment Rental

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 309298677
Report ID: 0950631
Date Opened: 07/25/2007

Site Address:
Hertz Equipment Rental
3040 E Miraloma Ave
Anaheim, CA 92806

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7353

NAICS: 532412/ Construction, Mining, and Forestry Machinery and Equipment Rental and Leasing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/24/2008

Emphasis:

Case Closed: 05/19/2009


Related Activity
Type Activity Nr Safety Health
Accident 102526605
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 3 3
Initial Penalty $18,000 $0 $0 $745 $0 $18,745
Current Penalty $0 $0 $0 $745 $0 $745
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 470 A 01/25/2008 01/30/2008 $0 $375 $0 02/25/2008 F - Formal Settlement Citation has been deleted.
2. 01002 Other 450 A01 01/25/2008 01/30/2008 $185 $185 $0 -  
3. 01003 Other 489 A 01/25/2008 01/30/2008 $185 $185 $0 -  
4. 02001 Other 450 A01 01/25/2008 06/26/2008 $375 $18,000 $0 02/25/2008 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201149481
Event: 07/25/2007
Employee Is Burned by Flash Fire

On July 25, 2007, Employee #1 was fueling a boom lift (JLG Boom Lift, Model N0. 600A, Serial No. 30009922) from a 485-gallon LPG tank (1980, Hanson, Serial No. 210509). He drove the boom lift to the LPG storage tank area and turned off the vehicle. The employee connected the fuel hose from the LPG storage tank to the fuel tank fill valve on the boom lift; and opened the fuel tank bleeder valve and the main fill valve on the storage tank. He activated the storage tank pump to start fueling. When he went to check the bleeder valve on the fuel tank, white smoke began to exit from the top of the fuel tank. There was a flash fire that knocked him to the ground. Employee #1 suffered second degree burns to his face, upper extremities, eye and mouth; and was hospitalized. The employee was not smoking and the ignition source for the fire was never determined.

Keywords: BURN, EYE, BOOM TRUCK, MOUTH, REFUELING, FIRE, LP GAS, ARM, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309298677 Hospitalized injury Burn/Scald(Heat) Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close