Powered by GoogleTranslate

Inspection Detail

Inspection: 309298115 - Cytec Engineered Materials

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 309298115
Report ID: 0950631
Date Opened: 05/31/2007

Site Address:
Cytec Engineered Materials
1440 N. Kraemer Blvd
Anaheim, CA 92806

Mailing Address:
1440 N. Kraemer, Anaheim, CA 92806

Union Status: Union

SIC:2821

NAICS: 325211/Plastics Material and Resin Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/26/2007

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/20/2008


Related Activity
Type Activity Nr Safety Health
Accident 102485604
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $22,500 $0 $0 $0 $0 $22,500
Current Penalty $18,000 $0 $0 $0 $0 $18,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3314 C 07/27/2007 08/01/2007 $18,000 $22,500 $0 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201148806
Event: 01/29/2007
Worker Amputates Fingertip in Machine Accident

On January 29, 2007, a control operator was employed by a manufacturer of composite materials. The worker was assigned to clean the Number 3 Graco resin pump. The pump was connected to a source of air and was lowered into a 5-gallon pail of acetone so that the shaft and paddle were immersed in the acetone. The pump was turned on, and solvent circulated through the system. The process was to be repeated with a second pail of acetone to ensure proper cleaning. After the first cycle was completed, the worker closed the air ball-valve that fed the pump and reached for the first pail. The priming piston activated, and the pump's paddle caught the tip of the worker's gloved left ring finger and pinched it. The worker's fingertip was crushed, and his finger was surgically amputated at the first joint. The worker did not require hospitalization.

Keywords: AMPUTATED, FINGER, GLOVE, CLEANING, MACHINE OPERATOR, CAUGHT BY, ACETONE, CRUSHED, PUMP, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309298115 Non Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.