Powered by GoogleTranslate

Inspection Detail

Inspection: 309177582 - Roof-Spec Inc

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 309177582
Report ID: 0522500
Date Opened: 07/25/2005

Site Address:
Roof-Spec Inc
1000 S. Front Street
Columbus, OH 43206

Mailing Address:
9 Hillandale Drive, Newark, OH 43055

Union Status: NonUnion

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/25/2005

Emphasis: S:Construction Fatalities

Case Closed: 12/21/2005


Related Activity
Type Activity Nr Safety Health
Accident 100752260
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $1,875 $0 $0 $0 $0 $1,875
Current Penalty $1,875 $0 $0 $0 $0 $1,875
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260451 F06 08/15/2005 09/02/2005 $1,500 $1,500 $0 -  
2. 01002 Serious 19260453 B02 V 08/15/2005 09/02/2005 $375 $375 $0 -  

Investigation Summary

Investigation Nr: 200758035
Event: 07/22/2005
Employee electrocuted when aerial lift strikes power line

At approximately 4:40 p.m. on June 22, 2005, Employee #1 was using a JLG aerial lift to install trim around the doorways of newly built townhouses. He was moving the lift when he contacted a 7,400-volt overhead power line. Employee #1 was electrocuted, sustaining second-degree burns to his head, back, and right arm. Employee #1 had completed jobs similar to this one during the seven years he worked for Roof-Spec, Inc., and the company had a written safety program that addressed preventing electrocutions when working near power lines. The company also had a written safety program that covered wearing fall protection when working from aerial lifts, but Employee #1 was not wearing a harness and lanyard.

Keywords: INSTALLING, OVERHEAD POWER LINE, ELECTRICAL, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, FALL PROTECTION, AERIAL LIFT, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309177582 Fatality Electric Shock Construction trades, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.