Inspection Detail
Inspection: 308820075 - Bosch Robert Llc
Inspection Information - Office: Miosha General Industry Safety & Health Division
Site Address:
Bosch Robert Llc
3737 Red Arrow Hwy
St Joseph, MI 49085
Mailing Address:
, , 00000
Union Status: Union
SIC:3714
NAICS: 336340/Motor Vehicle Brake System Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/13/2008
Planning Guide: Safety-Manufacturing
Emphasis: S:Amputations, S:Enf Targeted, S:Noise, S:Transportation Equipment
Case Closed: 09/11/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102458163 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $18,900 | $0 | $0 | $0 | $0 | $18,900 |
| Current Penalty | $11,400 | $0 | $0 | $0 | $0 | $11,400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 4081400202 | 07/10/2008 | 07/28/2008 | $3,840 | $6,300 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 4081400402 | 07/10/2008 | 07/28/2008 | $0 | $0 | $0 | I - Informal Settlement | ||
| 3. | 01002 | Serious | 4081400409 | 07/10/2008 | 07/28/2008 | $3,780 | $6,300 | $0 | I - Informal Settlement | ||
| 4. | 01003A | Serious | 4081400502 | 07/10/2008 | 07/28/2008 | $3,780 | $6,300 | $0 | I - Informal Settlement | ||
| 5. | 01003B | Serious | 4081400901 | 07/10/2008 | 07/28/2008 | $0 | $0 | $0 | - |
Investigation Summary
On January 8, 2008, Employee #1 was checking the fuse clips on an individual bucket in a 480 distribution panel that supplied power to a lighting transformer. He was checking the clips and lugs to determine the reason that a thermal image photo showed that this area of the panel was heating up. He had opened the disconnect on the front of the individual bucket and removed the three fuses. At some point, there was an arc blast and the employee was burned. Employee #1 died of complications from his burns.
Keywords: BURN, ELECTRIC ARC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 308820075 | Fatality | Burn/Scald(Heat) | Occupation not reported |