Inspection Detail
Inspection: 308682962 - Wells Dairy, Inc.
Inspection Information - Office: Omaha Area Office
Site Address:
Wells Dairy, Inc.
7006 J Street
Omaha, NE 68117
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2024
NAICS: 311520/Ice Cream and Frozen Dessert Manufacturing
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/27/2006
Emphasis:
Case Closed: 12/14/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 205049356 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
| Current Penalty | $0 | $0 | $0 | $2,000 | $0 | $2,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 5A0001 | 10/23/2006 | 11/10/2006 | $2,000 | $2,500 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 was connecting a pipe from a large tank of yogurt to a main supply line so that it could be transferred to other tanks. The process involves removing a cap and making the connection. Employee #1 assumed a valve was closed when he removed the cap. The valve had not been closed and milk at a temperature of approximately 180 degrees Fahrenheit gushed out and burned him. Employee #1 was hospitalized.
Keywords: BURN, HEAT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 308682962 | Hospitalized injury | Burn/Scald(Heat) | Miscellaneous machine operators, n.e.c. |
Translate