Powered by GoogleTranslate

Inspection Detail

Inspection: 308512516 - Crs Roofing Services

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 308512516
Report ID: 0352450
Date Opened: 02/15/2005

Site Address:
Crs Roofing Services
3135 Universtity Boulevard
Kensington, MD 20895

Mailing Address:
4700 Upshur Street, Bladensburg, MD 20710

Union Status: NonUnion

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/19/2005

Planning Guide: Safety-Construction

Emphasis: S:Electrocution, S:Falls

Case Closed: 05/04/2006


Related Activity
Type Activity Nr Safety Health
Accident 102357308
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $39,250 $0 $0 $0 $39,250
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19261053 B12 05/13/2005 05/18/2005 $7,000 $39,250 $0 06/02/2005 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202354692
Event: 02/15/2005
Electric Shock - Contact with Overhead Line thru Ladder

A crew foreman and another employee were at an apartment complex inspecting and repairing a leaking roof. They erected an aluminum ladder and extended it to about 10.4 meters to reach the 8.5-meter-high roof. The employees climbed to the roof, inspected it, and took photographs of the area in need of repair. They then descended to the ground. As they were moving the ladder, it contacted a 7.6-kilovolt overhead power line located 10.3 meters above the ground and approximately 4 meters from the building. Both employees were holding the ladder when it contacted the power line. The crew foreman received an electric shock and sustained severe burns on his hands and feet. His burns resulted in the surgical amputation of his lower left leg, several fingers, and one toe. He was hospitalized for his injuries. The second employee was electrocuted.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, METAL LADDER, ELECTRIC SHOCK, E GI IB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308512516 Hospitalized injury Electric Shock Supervisors; carpenters and related workers
2 308512516 Fatality Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close