Inspection Detail
Inspection Information - Office: Madison | ||||
---|---|---|---|---|
Nr: 308382324 | Report ID: 0523300 | Open Date: 10/03/2005 | ||
Central Storage & Warehouse Company | ||||
4309 Cottage Grove Road Madison, WI 53716 | Union Status: Union | |||
SIC: 4222/Refrigerated Warehousing and Storage | ||||
NAICS: 493120/Refrigerated Warehousing and Storage | ||||
Inspection Type: | Referral | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 12/16/2005 | |
Planning Guide: | Safety-Manufacturing | Close Case: | 03/13/2006 | |
Related Activity: | Type | ID | Safety | Health |
Referral | 200803856 | Yes |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 8 | 1 | 9 | |||
Current Violations | 3 | 4 | 7 | |||
Initial Penalty | $13,750 | $0 | $0 | $600 | $0 | $14,350 |
Current Penalty | $5,500 | $0 | $0 | $0 | $0 | $5,500 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001A | Serious | 19100023 C01 | 01/09/2006 | 01/20/2006 | $2,500 | $2,500 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19100067 C02 V | 01/09/2006 | 01/20/2006 | $0 | $0 | $0 | I - Informal Settlement | ||
3. | 01002 | Serious | 19100119 J02 | 01/09/2006 | 07/01/2006 | $1,250 | $1,250 | $0 | I - Informal Settlement | ||
Deleted | 4. | 01003 | Serious | 19100119 J06 II | 01/09/2006 | 02/11/2006 | $0 | $1,250 | $0 | I - Informal Settlement | |
Deleted | 5. | 01004 | Serious | 19100132 D01 | 01/09/2006 | 01/20/2006 | $0 | $2,500 | $0 | I - Informal Settlement | |
6. | 01005 | Serious | 19100132 F01 | 01/09/2006 | 01/20/2006 | $1,750 | $2,500 | $0 | I - Informal Settlement | ||
7. | 01006 | Other | 19100134 E01 | 01/09/2006 | 01/27/2006 | $0 | $1,250 | $0 | I - Informal Settlement | ||
8. | 01007 | Other | 19100134 F01 | 01/09/2006 | 02/11/2006 | $0 | $1,250 | $0 | I - Informal Settlement | ||
9. | 01008 | Other | 19100134 K01 | 01/09/2006 | 01/27/2006 | $0 | $1,250 | $0 | I - Informal Settlement | ||
10. | 02001 | Other | 19030019 D01 | 03/08/2006 | 03/27/2006 | $0 | $600 | $0 | I - Informal Settlement |
Accident Investigation Summary | ||||||
Summary Nr: 200801447 | Event: 10/03/2005 | Employee'S Hand Is Burned When Ammonia Escapes | ||||
On October 4, 2005, Employee #1 was working as a refrigeration mechanic. An ammonia system valve in freezer Number 7 was being turned, when the bonnet came loose with the wheel, releasing approximately 100 to 200 lbs of ammonia. Employee #1 was 35 feet up without fall protection, and he had to slide down racking to escape. He gave notification to shut the system down and summoned the city's hazard materials team. The plant and the surrounding businesses were evacuated without incident. Employee #1 sustained first and second degree chemical burns on his left hand. He was not hospitalized. This was not the first time that the bonnet of that Hansen 1.25 in. shut off valve had come off when the valve was turned. This type of valve is now made with a bolt to prevent the bonnet from turning. | ||||||
Keywords: ammonia, venting, refrigerant, valve, chemical burn, fall protection, storage rack, refrigerator, hand | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 308382324 | Non Hospitalized injury | Burn(Chemical) | Occupation not reported |