Powered by GoogleTranslate

Inspection Detail

Inspection: 308339993 - United Subcontractors, Inc. Dba G & G Insulation

Inspection Information - Office: Boise Area Office

 

Inspection Nr: 308339993
Report ID: 1032500
Date Opened: 07/13/2005

Site Address:
United Subcontractors, Inc. Dba G & G Insulation
1300 E. Lake Ave.
Mccall, ID 83638

Mailing Address:
12000 W. Franklin Road, Boise, ID 87309

Union Status: NonUnion

SIC:1742

NAICS: 238310/Drywall and Insulation Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/13/2005

Emphasis: S:Immigrant

Case Closed: 10/27/2007


Related Activity
Type Activity Nr Safety Health
Accident 100231224
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 3 3
Initial Penalty $31,000 $0 $0 $0 $0 $31,000
Current Penalty $14,000 $0 $0 $0 $0 $14,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260020 B02 08/19/2005 10/20/2005 $4,000 $5,000 $0 I - Informal Settlement  
2. 01001B Serious 19260021 B02 08/19/2005 09/08/2005 $0 $0 $0 I - Informal Settlement  
3. 01002A Serious 19260403 B01 08/19/2005 08/25/2005 $4,000 $5,000 $0 I - Informal Settlement  
4. 01002B Serious 19260404 F06 08/19/2005 08/25/2005 $0 $0 $0 I - Informal Settlement  
5. 01002C Serious 19260404 F07 IVC 08/19/2005 08/25/2005 $0 $0 $0 I - Informal Settlement  
6. 01002D Serious 19260405 G02 IV 08/19/2005 08/25/2005 $0 $0 $0 I - Informal Settlement  
7. 01002E Serious 19260405 J01 IIIC 08/19/2005 08/25/2005 $0 $0 $0 I - Informal Settlement  
8. 01002F Serious 19260405 J01 IIID 08/19/2005 08/25/2005 $0 $0 $0 I - Informal Settlement  
9. 01002G Serious 19260416 E01 08/19/2005 08/25/2005 $0 $0 $0 I - Informal Settlement  
10. 01002H Serious 19260406 B02 08/19/2005 08/25/2005 $0 $7,000 $0 I - Informal Settlement  
11. 01002I Serious 19260404 A02 08/19/2005 08/25/2005 $0 $0 $0 I - Informal Settlement  
12. 01003A Serious 19260403 B02 08/19/2005 08/25/2005 $0 $7,000 $0 I - Informal Settlement Citation has been deleted.
13. 01003B Serious 19260404 A02 08/19/2005 08/25/2005 $0 $0 $0 I - Informal Settlement Citation has been deleted.
14. 01004 Serious 19260404 B01 II 08/19/2005 08/25/2005 $6,000 $7,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200231652
Event: 07/12/2005
Employee electrocuted by portable light

On July 12, 2005, Employee #1 was installing spray-on fiberglass insulation in a crawl space between metal web trusses beneath a one-story building. He was using a machine housed in a street-side truck to blow in the insulation. Employee #1 had been working less than an hour when he was discovered with burns on his chest and right arm. He had been electrocuted, and was nonresponsive when emergency assistance reached him. The temperature in the crawl space where Employee #1 had been working was 116 degrees F. He had been using a work light designed for household use, without a protective cage; the light was found broken, lying on his chest. No ground fault circuit interrupter was used in the circuit, and the extension cord's ground pin had been removed.

Keywords: BURN, PROTECTIVE GROUNDING, WORK RULES, ELECTROCUTED, CONSTRUCTION, ELEC CIRC PART--MISC, ELECTRIC LIGHT--PORT, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308339993 Fatality Electric Shock Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.