Powered by GoogleTranslate

Inspection Detail

Inspection: 307825653 - Schmautz Construction Co

Inspection Information - Office: Or-E-Portland - Safety 1 1054111

 

Inspection Nr: 307825653
Report ID: 1054111
Date Opened: 06/17/2004

Site Address:
Schmautz Construction Co
5540 Ne Columbia Blvd
Portland, OR 97213

Mailing Address:
Po Box 20188, Portland, OR 97294

Union Status: Union

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/30/2004

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/22/2005


Related Activity
Type Activity Nr Safety Health
Accident 101631372
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $12,500 $0 $0 $0 $0 $12,500
Current Penalty $5,500 $0 $0 $0 $0 $5,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260502 I02 09/24/2004 06/17/2004 $3,000 $5,000 $0 10/11/2004 L - State Settlement  
2. 01001B Serious 19260502 I03 09/24/2004 06/17/2004 $0 $0 $0 10/11/2004 L - State Settlement  
3. 01002 Serious 7010053 09/24/2004 09/29/2004 $1,500 $5,000 $0 10/11/2004 L - State Settlement  
4. 02003 Serious 701070021 C 09/24/2004 09/29/2004 $1,000 $2,500 $0 10/11/2004 L - State Settlement  

Investigation Summary

Investigation Nr: 201634557
Event: 06/17/2004
Employee falls through unsecured roof opening and dies

On or about June 17, 2004, Employee #1 was laying sheets of insulation on a flat roof approximately 20 ft above the ground. A coworker removed an exhaust fan, leaving an opening approximately 3-ft by 3-ft. The hole was covered with two pieces of insulation, 8-ft long by 2-ft wide by 4-in. thick. These sheets were not secured. As they were finishing the edge of the roof, they used these two sheets and replaced them with a similar piece 4-ft by 4-ft by 4-in. thick, again, not securing them. Employee #1 walked across the roof, wearing dark glasses, and kicked the pieces of unsecured insulation and fell into the hole. He sustained a massive head injury and died at the hospital.

Keywords: HEAD, ROOF, UNSECURED, UNSECURED PANEL, CONSTRUCTION, ROOFER, FALL, FALL PROTECTION, CONCUSSION, ROOF OPENING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307825653 Fatality Other Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.