Powered by GoogleTranslate

Inspection Detail

Inspection: 307578195 - Verizon

Inspection Information - Office: Providence Area Office

 

Inspection Nr: 307578195
Report ID: 0112300
Date Opened: 07/18/2006

Site Address:
Verizon
75 Oxford Street
Providence, RI 02904

Mailing Address:
21 City Hall, Lynn, MA 01901

Union Status: Union

SIC:4813

NAICS: 517110/Wired Telecommunications Carriers


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/10/2007

Emphasis:

Case Closed: 12/05/2013


Related Activity
Type Activity Nr Safety Health
Accident 100090497
Referral 200763506 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $10,000 $0 $0 $0 $0 $10,000
Current Penalty $10,000 $0 $0 $0 $0 $10,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100268 B06 01/11/2007 05/16/2007 $5,000 $5,000 $0 02/05/2007 F - Formal Settlement  
2. 01001B Serious 19100268 B07 01/11/2007 05/16/2007 $0 $0 $0 02/05/2007 F - Formal Settlement  
3. 01001C Serious 19100132 A 01/11/2007 03/01/2007 $5,000 $0 $0 02/05/2007 F - Formal Settlement  
4. 01001D Serious 19100132 D01 01/11/2007 03/01/2007 $0 $0 $0 02/05/2007 F - Formal Settlement  
5. 01001E Serious 19100268 C 01/11/2007 07/09/2007 $0 $0 $0 02/05/2007 F - Formal Settlement  
6. 01002A Serious 19100268 D03 II 01/11/2007 03/01/2007 $5,000 $5,000 $0 02/05/2007 F - Formal Settlement Citation has been deleted.
7. 01002B Serious 19100268 F01 01/11/2007 03/01/2007 $0 $0 $0 02/05/2007 F - Formal Settlement  
8. 01002C Serious 19100268 M01 01/11/2007 07/09/2007 $5,000 $0 $0 02/05/2007 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200090553
Event: 08/01/2006
Employee Is Burned by Arc Flash, Later Dies

On August 1, 2006, Employee #1, a splice service technician for Verizon, was working from a bucket truck, at a remote site in Providence, RI. Employee #1, who was the only worker at the site, was installing new fiber optic lines between two telephone poles, along a street. Electrical power lines ran between the two poles, as well as a guy to support the poles. Because of high temperatures, Employee #1 had a company-issued umbrella in the bucket to keep himself out of the sun. Apparently, Employee #1 attempted to raise the bucket, and when he did, either the work tray on the bucket or the umbrella pushed the guy up into one of the 7,800-volt electrical lines. An arc flash occurred, and Employee #1 caught on fire, sustaining severe burns to over 80 percent of his body. Approximately two weeks later, Employee #1 died from his injuries.

Keywords: ELECTRIC ARC, INSTALLING, OVERHEAD POWER LINE, ELECTRICAL, TELECOM WORK, FIRE, GUY, ELECTRICAL FAULT, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307578195 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.