Powered by GoogleTranslate

Inspection Detail

Inspection: 307035220 - Rodriguez Custom Painting

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 307035220
Report ID: 0950632
Date Opened: 10/17/2006

Site Address:
Rodriguez Custom Painting
13145 Ridgedale Drive
Poway, CA 92064

Mailing Address:
14231 Garden Road, Suite 12, Poway, CA 92064

Union Status: NonUnion

SIC:1721

NAICS: 238320/Painting and Wall Covering Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/05/2007

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 02/08/2013


Related Activity
Type Activity Nr Safety Health
Accident 101062719
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 13 17
Current Violations 3 14 17
Initial Penalty $38,250 $0 $0 $9,495 $0 $47,745
Current Penalty $11,700 $0 $0 $4,150 $0 $15,850
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/05/2007 03/10/2007 $1,500 $5,000 $0 03/01/2007 F - Formal Settlement  
2. 01002 Other 1509 A 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
3. 01003 Other 1509 B 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
4. 01004 Other 1512 C01 02/05/2007 03/10/2007 $150 $280 $0 03/01/2007 F - Formal Settlement  
5. 01005 Other 1512 E 02/05/2007 03/10/2007 $250 $465 $0 03/01/2007 F - Formal Settlement  
6. 01006 Other 5144 C01 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
7. 01007 Other 5144 E01 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
8. 01008 Other 5144 F01 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
9. 01009 Other 5144 G01 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
10. 01010 Other 5144 H01 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
11. 01011 Other 5144 K01 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
12. 01012 Other 5194 E01 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
13. 01013 Other 5194 G08 02/05/2007 03/10/2007 $150 $375 $0 03/01/2007 F - Formal Settlement  
14. 02001 Serious 5194 H01 E 02/05/2007 03/10/2007 $4,500 $6,750 $0 03/01/2007 F - Formal Settlement  
15. 03001 Serious 5144 D01 02/05/2007 02/14/2007 $4,500 $6,750 $0 03/01/2007 F - Formal Settlement  
16. 04001 Other 5416 C 02/05/2007 02/14/2007 $750 $6,750 $0 03/01/2007 F - Formal Settlement  
17. 05001 Serious 1534 B 02/05/2007 02/14/2007 $2,700 $18,000 $0 03/01/2007 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201070406
Event: 08/23/2006
Employee Is Burned in Explosion During Painting Operation

At approximately 4:30 p.m. on August 23, 2006, Employee #1 and a coworker were painting a kitchen of a single family home. Before work began, the supervisor brought two five gallon buckets of white wood undercoat and one five gallon bucket of lacquer thinner to the jobsite. The supervisor then instructed Employee #1 and the coworker to use for painting with a spray assembly. The kitchen of the residence was masked off from the other portions of the house creating a tent-like atmosphere. As Employee #1 was spraying underneath a wall mounted oven, an explosion occurred. A fire ball formed and struck the back kitchen wall, igniting the plastic sheeting used for masking off the area. Emergency services were contacted, and Employee #1 was taken to UCSD Burn Center, where he was hospitalized and treated for serious burn injuries. The accident investigation revealed that the explosion occurred due to an oven pilot light that was the source of ignition. The flammable vapor of the paint allowed the atmosphere to exceed the allowable Lower Explosive Limit (LEL), causing the explosion when introduced to the ignition source. The atmosphere was not tested prior to the explosion.

Keywords: BURN, FLAMMABLE VAPORS, CONSTRUCTION, PAINT, EXPLOSION, PAINTER, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307035220 Hospitalized injury Burn(Chemical) Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close