Powered by GoogleTranslate

Inspection Detail

Inspection: 307030528 - Delimex

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 307030528
Report ID: 0950632
Date Opened: 06/01/2005

Site Address:
Delimex
7878 Airway Rd
San Diego, CA 92173

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2099

NAICS: 311830/Tortilla Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/24/2005

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/13/2009


Related Activity
Type Activity Nr Safety Health
Accident 362423493
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $24,750 $0 $0 $0 $0 $24,750
Current Penalty $24,750 $0 $0 $0 $0 $24,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3314 C 10/24/2005 10/27/2005 $6,750 $6,750 $0 -  
2. 02001 Serious 3942 A 10/24/2005 10/27/2005 $18,000 $18,000 $0 -  

Investigation Summary

Investigation Nr: 201069093
Event: 05/24/2005
Employee's Thumb Is Amputated in Hopper

At approximately 12:00 on May 24, 2005, an employee was assigned to work in the dry warehouse pneumatic delivery system room. The employee dumped a 50-lb bag of rice into a Pfening Syncrogear Model Number 0405, 240-volt, three-phase, 50-horsepower motor (50Hz, 1745 rpm). The rice would fall through a stainless steel magnetic grate that was not secured to the hopper. The magnetic grate attracted pieces of metal from the food product. The food product flowed down to a stainless steel rotary valve pipe. A propeller, at the bottom, kept the product moving onto the rice soakers located 45 ft away in another part of the plant. The hopper was supposed to be deenergized and the magnetic grate removed and wiped down after each bag of food product was finished flowing through the hopper. The employee did not shut off the hopper, when cleaning a dry hopper and he removed the magnetic grate. He reached down into the hopper, and the rotating propeller at the bottom struck his left thumb, resulting in amputation of the tip with bone loss. He was taken to the hospital, where surgeons reattached the amputated digit. He was hospitalized for over 24 hours.

Keywords: AMPUTATED, FINGER, THUMB, LOCKOUT, STRUCK BY, HOPPER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307030528 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.