Powered by GoogleTranslate

Inspection Detail

Inspection: 306695974 - Grunley-Walsh

Inspection Information - Office: Baltimore Area Office

 

Inspection Nr: 306695974
Report ID: 0316100
Date Opened: 04/23/2004

Site Address:
Grunley-Walsh
Neob 17th St Nw
Washington, DC 20006

Mailing Address:
11910 Parklawn Dr Suite U, Rockville, MD 20852

Union Status: NonUnion

SIC:1623

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/13/2004

Emphasis:

Case Closed: 10/15/2004


Related Activity
Type Activity Nr Safety Health
Accident 102040474

Investigation Summary

Investigation Nr: 202023453
Event: 04/23/2004
Employee is killed by steam release

On April 23, 2004, Employee #1, a superintendent, was turning on a 10-in. valve to resupply pressurized steam to a building. The 10-in. drip blew off, exposing him to 250 psi steam at 408 degrees, and killing him.

Keywords: BURN, STEAM, HIGH PRESSURE, VALVE, PRESSURE RELEASE, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306695974 Fatality Burn/Scald(Heat) Construction trades, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.