Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 306645060 - Winchester Construction

Inspection Information - Office: Oklahoma City

Nr: 306645060Report ID: 0627700Open Date: 05/12/2004

Winchester Construction
7650 W. Charles Page Blvd
Sand Springs, OK 74063
Union Status: NonUnion
SIC: 1795/Wrecking and Demolition Work
NAICS: 238910/Site Preparation Contractors
Mailing: 2776 Country Rd 2324, Como, TX 75431

Inspection Type:Accident
Scope:Partial Advanced Notice:Y
Ownership:Private
Safety/Health:Safety Close Conference:06/25/2004
Emphasis: L:FallClose Case:09/08/2004

Related Activity:TypeIDSafetyHealth
 Accident100643493    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $4,000 $0 $0 $2,000 $0 $6,000
Current Penalty $3,000 $0 $0 $1,000 $0 $4,000
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19260416 A01 07/21/2004 07/25/2004 $1,500 $2,000 $0 I - Informal Settlement
  2. 01002A Serious 19260503 A01 07/21/2004 07/29/2004 $1,500 $2,000 $0 I - Informal Settlement
  3. 01002B Serious 19260501 B01 07/21/2004 07/29/2004 $0 $0 $0 -
  4. 02001 Other 19040039 A 07/21/2004 07/26/2004 $1,000 $2,000 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 200642882Event: 05/11/2004Employee Electrocuted By Power Line While Removing Sign
On May 11, 2004, Employee #1, part of a sign crew for Winchester Construction, was on a catwalk helping to remove a billboard. The sign was located approximately 4 ft 10 in. south of a 13.2-kilovolt overhead power line with a phase to ground of 7,620-kilovolts. He was at the northeast corner of the catwalk, removing a 9 ft tall metal conduit when it contacted the south and middle phases of the power line. Employee #1 was electrocuted and fell 36 ft 3 in. to the ground. He was wearing a fall protection harness and lanyard, but the lanyard was not secured to the catwalk.
Keywords: clearance, overhead power line, work rules, electrocuted, struck against, construction, fall, fall protection, advertising sign, tie-off
Inspection Degree Nature Occupation
1 306645060 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close