Powered by GoogleTranslate

Inspection Detail

Inspection: 306591058 - Fab-X/Metals, Inc.

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 306591058
Report ID: 0453710
Date Opened: 06/19/2003

Site Address:
Fab-X/Metals, Inc.
2207 N. Wesleyan Blvd.
Rocky Mount, NC 27804

Mailing Address:
P.O. Box 7127, Rocky Mount, NC 27804

Union Status: NonUnion

SIC:3499

NAICS: 332999/All Other Miscellaneous Fabricated Metal Product Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/02/2003

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/26/2003


Related Activity
Type Activity Nr Safety Health
Accident 100355122
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 8 10
Current Violations 2 8 10
Initial Penalty $5,600 $0 $0 $0 $0 $5,600
Current Penalty $2,400 $0 $0 $0 $0 $2,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100252 A02 XIIIA 10/16/2003 11/12/2003 $0 $2,800 $0 I - Informal Settlement Citation has been deleted.
2. 01001B Serious 19100252 A02 XIIIB 10/16/2003 11/12/2003 $0 $0 $0 A - Amendment Citation has been deleted.
3. 01001C Serious 19100252 A02 XIIIC 10/16/2003 11/12/2003 $0 $0 $0 A - Amendment Citation has been deleted.
4. 01001D Serious 19100252 A02 XIVA 10/16/2003 11/12/2003 $0 $0 $0 A - Amendment Citation has been deleted.
5. 01001E Serious 19100252 A02 XIVF 10/16/2003 11/12/2003 $0 $0 $0 A - Amendment Citation has been deleted.
6. 01001F Serious 19100252 A03 I 10/16/2003 11/12/2003 $1,000 $0 $0 I - Informal Settlement  
7. 01002A Serious 19100307 B02 I 10/16/2003 11/12/2003 $1,400 $2,800 $0 I - Informal Settlement  
8. 01002B Serious 19100107 E02 10/16/2003 11/12/2003 $0 $0 $0 I - Informal Settlement  
9. 02001 Other 19100022 A01 10/16/2003 11/12/2003 $0 $0 $0 -  
10. 02002 Other 19100132 D01 I 10/16/2003 11/12/2003 $0 $0 $0 -  
11. 02003 Other 19100134 C01 II 10/16/2003 11/12/2003 $0 $0 $0 -  
12. 02004 Other 19100134 M01 10/16/2003 11/12/2003 $0 $0 $0 -  
13. 02005 Other 19100157 G01 10/16/2003 11/12/2003 $0 $0 $0 -  
14. 02006 Other 19100178 L01 I 10/16/2003 11/12/2003 $0 $0 $0 -  
15. 02007 Other 19100303 G01 I 10/16/2003 10/21/2003 $0 $0 $0 -  
16. 02008A Other 19101200 E01 I 10/16/2003 11/12/2003 $0 $0 $0 -  
17. 02008B Other 19101200 E01 II 10/16/2003 11/12/2003 $0 $0 $0 -  
18. 02008C Other 19101200 E02 I 10/16/2003 11/12/2003 $0 $0 $0 -  
19. 02008D Other 19101200 E02 II 10/16/2003 11/12/2003 $0 $0 $0 -  
20. 02008E Other 19101200 H01 II 10/16/2003 11/12/2003 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200353191
Event: 06/17/2003
Two employees burned when drum explodes

On June 19, 2003, Employees #1 and #2 were cutting an empty VMP Naphtha drum with a plasma-arc cutter. The drum exploded, and both employees were hospitalized with severe burns.

Keywords: BURN, FLAMMABLE VAPORS, PPE, WORK RULES, DRUM, FIRE, NAPHTHA, EXPLOSION, ARC WELDING, CUTTING AND BURNING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306591058 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 306591058 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close