Powered by GoogleTranslate

Inspection Detail

Inspection: 306173923 - Southeastern Metal Products, Inc.

Inspection Information - Office: Nc Department Of Labor - Charlotte

 

Inspection Nr: 306173923
Report ID: 0453730
Date Opened: 09/09/2003

Site Address:
Southeastern Metal Products, Inc.
1420 Metals Drive
Charlotte, NC 28221

Mailing Address:
P.O. Box 217126, Charlotte, NC 28221

Union Status: NonUnion

SIC:3469

NAICS: 332116/Metal Stamping


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/11/2003

Planning Guide: Safety-Manufacturing

Emphasis: N:Amputate, S:Program Improvements

Case Closed: 11/18/2003


Related Activity
Type Activity Nr Safety Health
Accident 102093747
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 4 1 5
Initial Penalty $4,676 $0 $0 $0 $0 $4,676
Current Penalty $4,676 $0 $0 $0 $0 $4,676
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100147 C04 II 10/02/2003 11/20/2003 $1,925 $1,925 $0 -  
2. 01001B Serious 19100147 D04 I 10/02/2003 11/20/2003 $0 $0 $0 -  
3. 01001C Serious 19100147 C07 I 10/02/2003 11/20/2003 $0 $0 $0 -  
4. 01001D Serious 19100147 C07 IV 10/02/2003 11/20/2003 $0 $0 $0 -  
5. 01001E Serious 19100147 C06 I 10/02/2003 11/20/2003 $0 $0 $0 -  
6. 01002 Serious 19100212 A01 10/02/2003 11/20/2003 $688 $688 $0 -  
7. 01003A Serious 19100217 B14 II 10/02/2003 10/07/2003 $1,375 $1,375 $0 -  
8. 01003B Serious 19100217 E01 I 10/02/2003 11/20/2003 $0 $0 $0 -  
9. 01004A Serious 19100217 D09 I 10/02/2003 11/20/2003 $688 $688 $0 -  
10. 01004B Serious 19100217 D09 IV 10/02/2003 11/20/2003 $0 $0 $0 -  
11. 02001 Other 19100217 C03 VIID 10/02/2003 10/07/2003 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 202075495
Event: 07/07/2003
Employee injures finger while operating power press

On July 7, 2003, Employee #1 was operating a Johnson OBI part-revolution mechanical power press. The press was equipped with two palm-control buttons and a control reliability and brake monitor, Model Number SS-501, Serial Number 10372. The employee was removing a part from the bottom die when the press cycled. The press then stopped when the ram was close to dead center and the employee's right index and middle fingers were caught between the top and bottom die. He suffered two fractured fingers. The primary cause of the accident was determined to be a brake failure. The braking mechanism was loose, contained a defective seal, and was not lubricated, which caused stress on the brake mechanism and caused it not to operate properly. A secondary cause was that the timing interval was set too high above the machine stopping time. When the ram reached the top dead center, the brake did not hold the ram and allowed it to move to the bottom dead center. The brake monitor did not receive a fault signal and did not stop the ram.

Keywords: FRACTURE, POWER PRESS, FINGER, WORK RULES, EQUIPMENT FAILURE, LOCKOUT, TWO-HAND CONTROL, CAUGHT BETWEEN, POINT OF OPERATION, PRESS OPERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306173923 Non Hospitalized injury Fracture Punching and stamping press machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.