Powered by GoogleTranslate

Inspection Detail

Inspection: 305871238 - Quinlan Enterprises

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 305871238
Report ID: 0420600
Date Opened: 09/20/2002

Site Address:
Quinlan Enterprises
11486 Corporate Blvd.
Orlando, FL 32804

Mailing Address:
P.O. Box 32, Claxton, GA 30417

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/17/2003

Emphasis: L:Flcare, S:Construction, S:Construction Fatalities

Case Closed: 06/23/2003


Related Activity
Type Activity Nr Safety Health
Accident 102350956
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 2 2
Initial Penalty $7,400 $0 $0 $0 $0 $7,400
Current Penalty $0 $0 $0 $1,250 $0 $1,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19260100 A 03/17/2003 03/20/2003 $625 $1,250 $0 04/07/2003 F - Formal Settlement  
2. 01002 Serious 19260550 B02 03/17/2003 03/27/2003 $4,900 $4,900 $0 04/07/2003 F - Formal Settlement Citation has been deleted.
3. 01003 Other 19260760 B03 03/17/2003 03/20/2003 $625 $1,250 $0 04/07/2003 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202338166
Event: 09/19/2002
Employee falls off of roof beam

On September 19, 2002, Employee #1, a connector on a steel erection crew, was setting steel beams for the roof of a three-story building. He and the other connector, who was in radio communication with the crane operator, were each setting an end of a new steel beam between the flanges of two previously set beams. The new steel beam was lowered to the workers and Employee #1 clamped his end in place. The coworker then signaled the crane operator to slowly raise up his end of the beam, telling him to continue up and up until indicating to stop. The crane operator interpreted the coworkers OK to mean that the beam was set and that it was safe to hoist the load line. As the crane operator raised the load line, the new steel beam was also being raised; it became wedged so tightly in the flanges of the previously set steel beams that the new beam bent enough to break free. It shot up into the air while still attached to the load line, then fell back down to the end of the load line and began to bounce and spin around. The beam either struck Employee #1 knocking him off the roof beam he was on, or the bouncing and vibrations of the beam caused him to lose his balance. Employee #1 fell through an air conditioning duct at the third floor level, landing on the concrete surface one floor down. He sustained a severe skull fracture and was transported to the hospital, where he died later that night.

Keywords: BEAM, STEEL BEAM, ROOF, SKULL, STEEL ERECTION, FALL, FALL PROTECTION, STRUCK BY, LOST BALANCE, UNSTABLE POSITION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305871238 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close