Powered by GoogleTranslate

Inspection Detail

Inspection: 305476954 - G F Cole Corporation

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 305476954
Report ID: 0950635
Date Opened: 09/28/2004

Site Address:
G F Cole Corporation
21737 S Western Avenue
Torrance, CA 90501

Mailing Address:
21735 S Western Avenue, Torrance, CA 90501

Union Status: NonUnion

SIC:3053

NAICS: 339991/ Gasket, Packing, and Sealing Device Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/05/2004

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362467656
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations 1 4 5
Initial Penalty $22,950 $0 $0 $545 $0 $23,495
Current Penalty $3,710 $0 $0 $5,350 $0 $9,060
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 461 A 12/10/2004 01/19/2005 $275 $275 $0 08/15/2005 L - State Settlement  
2. 01002 Other 6151 C01 12/10/2004 01/19/2005 $135 $135 $0 08/15/2005 L - State Settlement  
3. 01003 Other 4199 A 12/10/2004 01/19/2005 $135 $135 $0 08/15/2005 L - State Settlement  
4. 02001 Serious 4206 A 12/10/2004 01/19/2005 $3,710 $4,950 $0 08/15/2005 L - State Settlement  
5. 03001 Other 3314 A 12/10/2004 01/19/2005 $4,805 $18,000 $0 08/15/2005 L - State Settlement  

Investigation Summary

Investigation Nr: 201036183
Event: 07/10/2004
Employee Suffers Amputation When Hand Caught in Machine

On July 10, 2004, the second shift employees were manufacturing gaskets using different machines such as punch presses, band saws and slithers. Employee #1 had been assigned to operate a green colored Kenco 20-ton press, Model Number 32101, Serial Number 32 30 166. Employee #1's job was to die-cut material called THV-2002 using die Number 2BD 272 OU 9608, a material that is used as insulation on battery packs which are installed on cordless power tools. Employee #1 was operating in continuous-mode a full-revolution press that was unguarded, using a foot pedal as the activating means. At one point into the operation, Employee #1 manually pulled out material that had stuck to the upper die, and then inadvertently pushed the foot pedal which resulted in the activation of the press he was working on. Employee #1 suffered the amputation of four of his fingers on his left hand. Employee #1 was treated for his injuries but was not hospitalized.

Keywords: AMPUTATED, FINGER, FOOT CONTROL, JAMMED, PRESS, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305476954 Non Hospitalized injury Amputation Punching and stamping press machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close