Powered by GoogleTranslate

Inspection Detail

Inspection: 305354201 - Essex Electric Inc

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 305354201
Report ID: 0950631
Date Opened: 06/30/2004

Site Address:
Essex Electric Inc
1075 N Patt St
Anaheim, CA 92803

Mailing Address:
, , 00000

Union Status: Union

SIC:3496

NAICS: 332618/Other Fabricated Wire Product Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/03/2004

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/22/2006


Related Activity
Type Activity Nr Safety Health
Accident 101140325
Complaint 77853299 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 2 1 3
Initial Penalty $39,375 $0 $0 $5,000 $0 $44,375
Current Penalty $20,700 $0 $0 $5,000 $0 $25,700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 01/07/2005 01/12/2005 $5,000 $5,000 $0 -  
2. 02001 Serious 4002 A 12/03/2004 12/08/2004 $2,700 $3,375 $0 I - Informal Settlement  
3. 03001 Serious 4186 B 12/03/2004 12/08/2004 $18,000 $18,000 $0 -  
4. 04001 Serious 3314 A 12/03/2004 12/08/2004 $0 $18,000 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201145695
Event: 06/05/2004
Employee's fingers are amputated by wire cutter in machine

At 5:15 a.m. on June 5, 2004, Employee #1 was making 25-ft-long coils of wire on a 'handi-wire' machine. This machine is activated by push buttons on a control panel at the front of the machine. When the coil length is reached, the operator activates the cut button on the panel, and the cut wire coil drops down onto a 4-in.-wide by 24-in.-long chute. There is a plastic guard with a 5-in.wide opening mounted at the rear of the chute 3 in. forward of the cutting knife. When a piece of wire became jammed before the chute, Employee #1 reached in through the opening in the guard and used his right thumb and index finger to grab the wire. The cutting knife came down and cut these two fingers. He was hospitalized for surgical reattachment of the thumb and treatment of an amputation of the index finger. There were no direct witnesses to the incident. The machine was not locked out/tagged out prior to the accident. The point of operation guard was inadequate to prevent employees from reaching the point of operation.

Keywords: KNIFE, AMPUTATED, FINGER, GUARD, WORK RULES, MACHINE OPERATOR, THUMB, JAMMED, LOCKOUT, POINT OF OPERATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305354201 Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.