Inspection Detail
Inspection: 305353765 - Cytec Engineered Materials
Inspection Information - Office: Santa Ana District Office
Site Address:
Cytec Engineered Materials
1440 N Kraemer Blvd
Anaheim, CA 92806
Mailing Address:
, , 00000
Union Status: Union
SIC:3087
NAICS: 325991/Custom Compounding of Purchased Resins
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/16/2004
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 09/22/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362474504 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $600 | $0 | $600 |
| Current Penalty | $0 | $0 | $0 | $600 | $0 | $600 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3314 B | 09/16/2004 | 10/09/2004 | $300 | $300 | $0 | - | ||
| 2. | 01002 | Other | 3314 H | 09/16/2004 | 10/09/2004 | $300 | $300 | $0 | - |
Investigation Summary
On April 9, 2004, Employee #1 was repairing a mixer. This 5-gallon mixer was manufactured by Myers Equipment Company under the model number 500A-3-141 and serial number 5-81. The mixer was not operating properly due to a loose sprocket. This sprocket and chain drive is located on the top part of the mixer and is normally guarded by a metal cover. This mixer is equipped with a delay circuit to turn the mixer on and off periodically. The employee did not turn the power off and removed the cover on the sprocket and chain while the mixer was off due to the delay cycle. He fixed the sprocket by tightening the set screws on the sprocket. When he tried to check the tension on the chain with his right hand, the mixer turned on with the delay circuit and his fingers were caught in the nip point of the sprocket and chain. The employee's right middle finger and half of his right index finger were amputated. Employee #1 was hospitalized for seven days.
Keywords: CHAIN, AMPUTATED, REPAIR, FINGER, MIXER, SPROCKET, NIP POINT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 305353765 | Hospitalized injury | Amputation | Industrial machinery repairers |
Translate