Powered by GoogleTranslate

Inspection Detail

Inspection: 305353260 - Crenshaw Die And Manufacturing Corporation

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 305353260
Report ID: 0950631
Date Opened: 01/27/2004

Site Address:
Crenshaw Die And Manufacturing Corporation
17152 Daimler St
Irvine, CA 92614

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3469

NAICS: 332116/Metal Stamping


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/25/2004

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/07/2008


Related Activity
Type Activity Nr Safety Health
Accident 362368417
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 2 1 3
Initial Penalty $22,050 $0 $0 $5,325 $0 $27,375
Current Penalty $16,785 $0 $0 $325 $0 $17,110
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 06/25/2004 06/30/2004 $0 $5,000 $0 F - Formal Settlement Citation has been deleted.
2. 01002 Other 4202 A 06/25/2004 07/08/2004 $325 $325 $0 07/13/2004 F - Formal Settlement  
3. 02001 Serious 4207 A 06/25/2004 06/30/2004 $16,200 $16,200 $0 07/13/2004 F - Formal Settlement  
4. 03001 Serious 4203 B 06/25/2004 07/08/2004 $585 $5,850 $0 07/13/2004 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201145075
Event: 12/31/2003
Punch Press Amputates Employee's Finger

At approximately 8:00 a.m. on December 31, 2003, Employee #1 was operating a Niagra full-revolution, 30-ton (Model A-3, Serial Number 16340) punch press located in the production area of a company that does tool and die design. The metal designs are processed using full-revolution punch presses, shears, and miscellaneous hand tools. The press had a piece of Plexiglas with a 4.5-in. by 5-in. opening in the lower quarter. This Plexiglas was used as the point of operation guard. The guard was not designed to prevent the operator's hand(s) from entering into the point of operation. In addition, the guard was not set up properly and maintained in an efficient working condition. The opening in the Plexiglas guard is for air hoses used to blow the stamped pieces forward. The press is equipped with a pedestal control and a foot pedal. Employee #1 stated he was not running on the single stroke mode. Employee #1 had the selector button on the continuous mode; however, he was using the foot pedal. The press was malfunctioning causing the pieces to get stuck. Employee #1 kept his foot on the pedal and reached through the opening in the Plexiglas to remove a piece of product. The press cycled and caught Employee #1's finger. Employee #1 sustained crushing injuries to the right middle finger with a partial amputation of the distal phalanx and was hospitalized.

Keywords: AMPUTATED, FINGER, GUARD, FOOT CONTROL, CRUSHED, POINT OF OPERATION, PUNCH PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305353260 Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.