Inspection Detail
Inspection: 305157901 - Owens Corning Foam Insulation, Llc
Inspection Information - Office: Naperville Area Office
Site Address:
Owens Corning Foam Insulation, Llc
2710 Laude Drive
Rockford, IL 61108
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3086
NAICS: 326140/Polystyrene Foam Product Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/27/2002
Emphasis:
Case Closed: 02/05/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 200821742 | Yes | |
| Referral | 200821767 | Yes | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
| Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 01/10/2003 | 01/15/2003 | $2,500 | $5,000 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 10:45 a.m. on December 26, 2002, Employees #1 and #2 had completed the repairs on a connection leak between the dynamic cooler and static mixer on Extrusion Line Number 1. Earlier, the dynamic cooler was turned on and begun heating the material in the line. Upon assessment of the equipment, a leak in the connection between the cooler and static mixer was discovered. Both pieces of equipment were shutdown and the connection removed for repair. Then following the repair and reattachment of the connector, the process equipment was started up, along with the extruder. As the material flowed through the lines and into the repaired connector between the dynamic cooler and the secondary extruder, the line ruptured spraying flaming polystyrene over the employees. Employee #1 and #2 received first, second, and third degree burns on their heads and faces. They were transported to a hospital, where they were administered medical treatment for their burns, and then released.
Keywords: BURN, HEAD, FLAMMABLE LIQUID, RUPTURE, FACE, FORMING MACHINE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 305157901 | Non Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 305157901 | Non Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate