Inspection: 304830227 - Unique Interiors Inc

Inspection Information - Office: Washington Region 1

Nr: 304830227Report ID: 1055310Open Date: 12/18/2001

Unique Interiors Inc
14126 51st Ave Ne
Marysville, WA 98271
Union Status: NonUnion
SIC: 5713/Floor Covering Stores
Mailing: 301 N Olympic, Arlington, WA 98223

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Health Close Conference:01/07/2002
Close Case:05/22/2002

Related Activity:TypeIDSafetyHealth
 Accident361236466    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 11 13
Current Violations 2 11 13
Initial Penalty $1,650 $0 $0 $0 $0 $1,650
Current Penalty $1,650 $0 $0 $0 $0 $1,650
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001A Serious 1550027006 C 02/12/2002 01/07/2002 $1,350 $1,350 $0 -
  2. 01001B Serious 06207005 02/12/2002 01/07/2002 $0 $0 $0 -
  3. 01002A Serious 80017030 02/12/2002 05/17/2002 $300 $300 $0 P - Petition to Mod Abatement
  4. 01002B Serious 80014005 02/12/2002 05/17/2002 $0 $0 $0 P - Petition to Mod Abatement
  5. 02001 Other 80016010 02/12/2002 03/17/2002 $0 $0 $0 -
  6. 02002 Other 80017005 02/12/2002 03/17/2002 $0 $0 $0 -
  7. 02003 Other 0620710701 02/12/2002 05/17/2002 $0 $0 $0 P - Petition to Mod Abatement
  8. 02004 Other 0620713001 02/12/2002 05/17/2002 $0 $0 $0 P - Petition to Mod Abatement
  9. 02005 Other 0620713104 02/12/2002 05/17/2002 $0 $0 $0 P - Petition to Mod Abatement
  10. 02006 Other 06207150 02/12/2002 05/17/2002 $0 $0 $0 P - Petition to Mod Abatement
  11. 02007 Other 06207160 02/12/2002 05/17/2002 $0 $0 $0 P - Petition to Mod Abatement
  12. 02008 Other 0620719001 02/12/2002 05/17/2002 $0 $0 $0 P - Petition to Mod Abatement
  13. 02009 Other 80013015 02/12/2002 03/17/2002 $0 $0 $0 -
  14. 02010 Other 0240002004 02/12/2002 05/17/2002 $0 $0 $0 P - Petition to Mod Abatement
  15. 02011 Other 0240002005 02/12/2002 03/17/2002 $0 $0 $0 -

Accident Investigation Summary
Summary Nr: 170238885Event: 12/17/2001Employees Burnt When Vapors Ignited A Gas Heater
Two employees of Unique Interiors Inc., were installing a bathtub surround in the bathroom of a single family home. While applying contact cement to the back of the tub surround, the vapors from the cement ignited the pilot light in a gas powered water heater. Because of the lack of ventilation, the vapors and the heater created a flat tire. Employee #1 was burned over 90 percent of his body and died. Employee #2 was burnt over 15 percent of his body and he was hospitalized.
Keywords: vapor, ventilation, heater, explosion
Inspection Degree Nature Occupation
1 304830227 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 304830227 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.